Suppr超能文献

耳鸣障碍量表的波兰语改编及其在耳鸣患者临床群体中的测试。

Adaptation of the Tinnitus Handicap Inventory into Polish and its testing on a clinical population of tinnitus sufferers.

作者信息

Skarzynski Piotr H, Raj-Koziak Danuta, J Rajchel Joanna, Pilka Adam, Wlodarczyk Andrzej W, Skarzynski Henryk

机构信息

a World Hearing Center , Institute of Physiology and Pathology of Hearing , Warsaw/Kajetany , Poland.

b Heart Failure and Cardiac Rehabilitation Department , 2nd Faculty of Medicine, Medical University of Warsaw , Warsaw , Poland , and.

出版信息

Int J Audiol. 2017 Oct;56(10):711-715. doi: 10.1080/14992027.2017.1319080. Epub 2017 May 24.

Abstract

OBJECTIVE

To describe how the Tinnitus Handicap Inventory (THI) was translated into Polish (THI-POL) and to present psychometric data on how well it performed in a clinical population of tinnitus sufferers.

DESIGN

The original version of THI was adapted into Polish. The reliability of THI-POL was investigated using test-retest, Cronbach's alpha, endorsement rate and item-total correlation. Construct validity and convergent validity were also assessed based on confirmatory factor analysis, inter-item correlation and Pearson product-moment correlations using subscale A (Tinnitus) of the Tinnitus and Hearing Survey (THS-POL); divergent validity was checked using subscale B (Hearing) of THS-POL.

STUDY SAMPLE

A group of 167 adults filled in THI-POL twice over their three-day hospitalisation period.

RESULTS

Test-retest reliability for the total THI-POL scores was strong (r = 0.91). Cronbach's alpha coefficient for the total score was high (r = 0.95), confirming the questionnaire's stability. Confirmatory factor analysis (CFA) and inter-item correlation did not confirm the three-factor model. Convergent validity from the Tinnitus subscale of THS showed a positive strong (r = 0.75) correlation. Divergent validity showed only a moderate correlation. All analyses were statistically significant (p <  0.01).

CONCLUSIONS

THI-POL is a valid and reliable self-administered tool, which allows the overall tinnitus handicap of Polish-speaking patients to be effectively assessed.

摘要

目的

描述耳鸣障碍量表(THI)如何被翻译成波兰语版本(THI-POL),并展示其在耳鸣患者临床群体中的心理测量数据,以说明该量表的表现情况。

设计

将THI的原始版本改编为波兰语版本。通过重测法、克朗巴哈系数、认可率和项目-总分相关性来研究THI-POL的信度。还基于验证性因素分析、项目间相关性以及使用耳鸣与听力调查(THS-POL)的A分量表(耳鸣)的皮尔逊积差相关性来评估结构效度和收敛效度;使用THS-POL的B分量表(听力)来检验区分效度。

研究样本

一组167名成年人在为期三天的住院期间两次填写THI-POL。

结果

THI-POL总分的重测信度很强(r = 0.91)。总分的克朗巴哈系数很高(r = 0.95),证实了问卷的稳定性。验证性因素分析(CFA)和项目间相关性未证实三因素模型。THS耳鸣分量表的收敛效度显示出强正相关(r = 0.75)。区分效度仅显示出中度相关性。所有分析均具有统计学意义(p < 0.01)。

结论

THI-POL是一种有效且可靠的自我管理工具,能够有效评估说波兰语患者的整体耳鸣障碍程度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验