Suppr超能文献

短期佩戴软性隐形眼镜后角膜缘巩膜的变化。

Corneo-scleral limbal changes following short-term soft contact lens wear.

作者信息

Consejo Alejandra, Bartuzel Maciej M, Iskander D Robert

机构信息

Department of Biomedical Engineering, Wroclaw University of Science and Technology, Poland.

Department of Biomedical Engineering, Wroclaw University of Science and Technology, Poland.

出版信息

Cont Lens Anterior Eye. 2017 Oct;40(5):293-300. doi: 10.1016/j.clae.2017.04.007. Epub 2017 May 25.

Abstract

PURPOSE

To assess whether short-term soft contact lens wear alters the anterior eye surface.

METHODS

Twenty-two neophyte subjects wore soft contact lenses for a period of five hours. Topography based corneo-scleral limbal radius estimates were derived from height measurements acquired with a corneo-scleral profilometer. Additionally, central corneal thickness (CCT), anterior chamber depth (ACD), corneal curvature radius (R) and white-to-white (WTW) diameter were acquired with an OCT-assisted biometer. Measurements were obtained without lens wear (baseline), immediately after lens removal following five hours of wear and three hours after lens removal.

RESULTS

Short-term soft contact lens wear significantly modifies corneo-scleral limbal radius (mean±SD: 130±74μm, p << 0.001) and the changes are repeatable. In contrast, the WTW diameter and R were not modified. ACD and CCT were significantly affected but no significant correlations were found between the increment of the limbal radius and the decrease in ACD and CCT. Limbal radius increment was reversed three hours after lens removal for 68% of the subjects but the time course of this reversal was not uniform.

CONCLUSIONS

It is possible to accurately quantify limbal radius changes as a consequence of soft contact lens wear. The increment in the limbal diameter could reach over 0.5mm but that alteration does not correspond to changes in WTW diameter and it was not observable to the examiner using a slit lamp. Assessing topographical limbus after contact lens wear could be a tool to optimize the selection of the contact lens, from the perspective of anterior eye surface changes.

摘要

目的

评估短期佩戴软性隐形眼镜是否会改变眼前节表面。

方法

22名初戴者佩戴软性隐形眼镜5小时。基于地形图的角巩膜缘半径估计值来自用角巩膜轮廓仪获取的高度测量值。此外,使用光学相干断层扫描(OCT)辅助生物测量仪测量中央角膜厚度(CCT)、前房深度(ACD)、角膜曲率半径(R)和白到白(WTW)直径。在不佩戴镜片时(基线)、佩戴5小时后立即取下镜片后以及取下镜片3小时后进行测量。

结果

短期佩戴软性隐形眼镜显著改变角巩膜缘半径(平均值±标准差:130±74μm,p << 0.001),且这些变化是可重复的。相比之下,WTW直径和R未发生改变。ACD和CCT受到显著影响,但角巩膜缘半径的增加与ACD和CCT的减少之间未发现显著相关性。68%的受试者在取下镜片3小时后角巩膜缘半径增加得到逆转,但这种逆转的时间进程并不一致。

结论

有可能准确量化软性隐形眼镜佩戴导致的角巩膜缘半径变化。角巩膜缘直径的增加可能超过0.5mm,但这种改变与WTW直径的变化不对应,并且使用裂隙灯检查时检查者无法观察到。从眼前节表面变化的角度来看,评估隐形眼镜佩戴后的地形图角膜缘可能是优化隐形眼镜选择的一种工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验