Axelson Peter W, Hurley Seanna L
a Beneficial Designs, Inc. , Minden , NV , USA.
Disabil Rehabil Assist Technol. 2018 May;13(4):379-387. doi: 10.1080/17483107.2017.1328618. Epub 2017 May 27.
The firmness and stability of indoor and outdoor surfacing are critical to the accessibility and safety of all environments for people with mobility impairments and/or who use mobility devices. ASTM F1951 laboratory test procedures include pass/fail criteria for determining playground surface accessibility by comparing the work to propel up a 1:14 (7.1%) grade ramp to that of the test surface in a wheelchair. A portable instrumented surface indenter (ISI) was developed to validate that accessibility results obtained in the laboratory are maintained in the field where the surface is installed and used.
Accessibility measurements have been made on indoor and outdoor surfaces tested in the laboratory using both the ASTM F1951 and the ISI over 13 years. Correlations between these two methods were calculated.
A strong correlation has been demonstrated for the sum of the ISI firmness and stability results compared to the sum of the ASTM F1951 straight propulsion and turning results (R=0.9006).
The portable ISI can be used to verify that the firmness and stability of an installed surface in the field correlates to the accessibility results of the surface tested in the laboratory concurrently according to ASTM F1951 and the ISI. Implications for Rehabilitation The Instrumented Surface Indenter (ISI) allows for surfaces in all environments to be tested for firmness and stability, which is critical for wheelchair user safety, especially during rehabilitation when learning to use a wheelchair. The ISI allows for surfaces in all environments to be tested for firmness and stability, which increases access to all indoor and outdoor surfaces, thereby improving the quality of life for people who have mobility impairments and/or use mobility devices, such as canes, crutches, walkers, and wheelchairs. Using the ISI to test the firmness and stability of installed playground surfaces increases access to playgrounds for children with mobility impairments, facilitating developmentally critical peer-play opportunities for children who use mobility devices. Using the ISI to test the firmness and stability of installed playground surfaces increases access to playgrounds for people with mobility impairments, allowing adults who use a mobility device to supervise and play with children in their lives.
室内外地面的坚固性和稳定性对于行动不便者和/或使用移动设备的人在所有环境中的可达性和安全性至关重要。ASTM F1951实验室测试程序包括通过比较在轮椅上推动一个1:14(7.1%)坡度斜坡所需的功与测试表面所需的功来确定游乐场地面可达性的通过/失败标准。开发了一种便携式仪器化表面压头(ISI),以验证在实验室获得的可达性结果在地面安装和使用的现场是否得以保持。
在13年的时间里,使用ASTM F1951和ISI对实验室测试的室内外地面进行了可达性测量。计算了这两种方法之间的相关性。
与ASTM F1951直线推进和转弯结果的总和相比,ISI坚固性和稳定性结果的总和显示出很强的相关性(R = 0.9006)。
便携式ISI可用于验证现场安装地面的坚固性和稳定性与根据ASTM F1951和ISI在实验室同时测试的地面可达性结果相关。康复意义 仪器化表面压头(ISI)可对所有环境中的地面进行坚固性和稳定性测试,这对于轮椅使用者的安全至关重要,尤其是在学习使用轮椅的康复过程中。ISI可对所有环境中的地面进行坚固性和稳定性测试,这增加了对所有室内外地面的可达性,从而改善了行动不便者和/或使用移动设备(如手杖, 拐杖, 助行器和轮椅)的人的生活质量。使用ISI测试已安装的游乐场地面的坚固性和稳定性,增加了行动不便儿童进入游乐场的机会,为使用移动设备的儿童提供了对发育至关重要的同伴玩耍机会。使用ISI测试已安装的游乐场地面的坚固性和稳定性,增加了行动不便者进入游乐场的机会,使使用移动设备的成年人能够在生活中监督孩子并与他们一起玩耍。