Suppr超能文献

提出间歇性外斜视的新评分系统:迈向更好的控制评估。

Proposing a new scoring system in intermittent exotropia: towards a better assessment of control.

作者信息

Kim Hyuna, Kim Dae Hee, Ahn Hyosook, Lim Hyun Taek

机构信息

Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea.

Department of Ophthalmology, University of Seonam College of Medicine, MyongJi Hospital, Goyang, South Korea.

出版信息

Can J Ophthalmol. 2017 Jun;52(3):235-239. doi: 10.1016/j.jcjo.2016.08.017. Epub 2016 Oct 27.

Abstract

OBJECTIVE

There is a clinical need for a valid and reliable assessment system to quantify the severity and measure the progression of intermittent exotropia. We have developed a new scoring system (Look And Cover, then Ten seconds of Observation Scale for Exotropia [LACTOSE]) based on the examinee's potential to regain the phoria for both distance and near fixation. The test takes only 1 minute to complete. The aim of this study was to evaluate the reliability and validity of LACTOSE.

METHODS

The LACTOSE was created by incorporating both distance and near score (0-4 each) into a total score ranging from 0 to 8. A total of 235 consecutive patients with intermittent exotropia were prospectively evaluated using this new scoring system. Inter-rater and test-retest reliability was assessed from a cohort of 10 patients who were video recorded while undergoing the scoring testing and then scored by 10 trained ophthalmologists independently. Construct validity was studied by comparison with clinical variables indicating disease severity.

RESULTS

Inter-rater reliability was good for both distance and near (intraclass correlation coefficient [ICC] = 0.729 and 0.818). Test-retest reliability was excellent for both distance and near (ICC = 0.849 and 0.727). Median scores for distance, near, and total were 3, 1, and 4, respectively. A broad representation of the total scores was significantly linked to the age of onset and the amount of exotropia (r = 0.194, p = 0.003 and r = 0.159, p < 0.001).

CONCLUSIONS

We found that our newly developed scoring system is a reliable and valid tool for assessing the severity of intermittent exotropia. This new measure can be implemented easily and efficiently across diverse clinical settings.

摘要

目的

临床上需要一种有效且可靠的评估系统来量化间歇性外斜视的严重程度并衡量其进展情况。我们基于受检者在远距离和近距离注视时恢复隐斜的能力,开发了一种新的评分系统(注视、遮盖,然后十秒外斜视观察量表[LACTOSE])。该测试只需1分钟即可完成。本研究的目的是评估LACTOSE的可靠性和有效性。

方法

LACTOSE通过将远距离和近距离得分(各为0 - 4分)合并为总分0至8分来创建。使用这个新的评分系统对235例连续的间歇性外斜视患者进行前瞻性评估。从10例患者组成的队列中评估评分者间信度和重测信度,这些患者在进行评分测试时被录像,然后由10名经过培训的眼科医生独立评分。通过与表明疾病严重程度的临床变量进行比较来研究结构效度。

结果

评分者间信度在远距离和近距离方面均良好(组内相关系数[ICC]分别为0.729和0.818)。重测信度在远距离和近距离方面均极佳(ICC分别为0.849和0.727)。远距离、近距离和总分的中位数分别为3分、1分和4分。总分的广泛分布与发病年龄和外斜视度数显著相关(r = 0.194,p = 0.003;r = 0.159,p < 0.001)。

结论

我们发现新开发的评分系统是评估间歇性外斜视严重程度的可靠且有效的工具。这种新方法可以在不同临床环境中轻松、高效地实施。