Suppr超能文献

双氯芬酸在局部作用的皮肤科制剂中的局部生物利用度。

Topical bioavailability of diclofenac from locally-acting, dermatological formulations.

作者信息

Cordery S F, Pensado A, Chiu W S, Shehab M Z, Bunge A L, Delgado-Charro M B, Guy R H

机构信息

Department of Pharmacy & Pharmacology, University of Bath, Bath, UK.

Chemical and Biological Engineering, Colorado School of Mines, Golden, CO, USA.

出版信息

Int J Pharm. 2017 Aug 30;529(1-2):55-64. doi: 10.1016/j.ijpharm.2017.06.063. Epub 2017 Jun 19.

Abstract

Assessment of the bioavailability of topically applied drugs designed to act within or beneath the skin is a challenging objective. A number of different, but potentially complementary, techniques are under evaluation. The objective of this work was to evaluate in vitro skin penetration and stratum corneum tape-stripping in vivo as tools with which to measure topical diclofenac bioavailability from three approved and commercialized products (two gels and one solution). Drug uptake into, and its subsequent clearance from, the stratum corneum of human volunteers was used to estimate the input rate of diclofenac into the viable skin layers. This flux was compared to that measured across excised porcine skin in conventional diffusion cells. Both techniques clearly demonstrated (a) the superiority in terms of drug delivery from the solution, and (b) that the two gels performed similarly. There was qualitative and, importantly, quantitative agreement between the in vitro and in vivo measurements of drug flux into and beyond the viable skin. Evidence is therefore presented to support an in vivo - in vitro correlation between methods to assess topical drug bioavailability. The potential value of the stratum corneum tape-stripping technique to quantify drug delivery into (epi)dermal and subcutaneous tissue beneath the barrier is demonstrated.

摘要

评估旨在作用于皮肤内部或下方的局部应用药物的生物利用度是一项具有挑战性的目标。许多不同但可能互补的技术正在评估中。这项工作的目的是评估体外皮肤渗透和体内角质层胶带剥离,作为测量三种已批准和商业化产品(两种凝胶和一种溶液)中局部用双氯芬酸生物利用度的工具。通过测量人体志愿者角质层对药物的摄取及其随后的清除率,来估计双氯芬酸进入有活力皮肤层的输入速率。将该通量与在传统扩散池中通过切除的猪皮肤测量的通量进行比较。两种技术都清楚地表明:(a)溶液给药在药物递送方面具有优越性;(b)两种凝胶的表现相似。在药物进入和穿过有活力皮肤的体外和体内测量之间,存在定性且重要的是定量的一致性。因此,有证据支持评估局部药物生物利用度方法之间的体内 - 体外相关性。证明了角质层胶带剥离技术在量化药物递送至屏障下方的(表皮)和皮下组织方面的潜在价值。

相似文献

引用本文的文献

10
Predicting skin permeability using HuskinDB.利用 HuskinDB 预测皮肤渗透率。
Sci Data. 2022 Sep 23;9(1):584. doi: 10.1038/s41597-022-01698-4.

本文引用的文献

7
Percutaneous absorption in man: in vitro-in vivo correlation.人体经皮吸收:体外-体内相关性。
Skin Pharmacol Physiol. 2011;24(4):224-30. doi: 10.1159/000324884. Epub 2011 Mar 31.
10
The tape stripping procedure--evaluation of some critical parameters.胶带剥离程序——一些关键参数的评估
Eur J Pharm Biopharm. 2009 Jun;72(2):317-23. doi: 10.1016/j.ejpb.2008.08.008. Epub 2008 Aug 19.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验