Li Xin, Zhang Yaoshen, Zhang Qiang, Zhao Changsong, Liu Kun
Department of Orthopedics, Beijing Ditan Hospital, Capital Medical University, Beijing, China.
Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
Acta Ortop Bras. 2017 Mar-Apr;25(2):67-70. doi: 10.1590/1413-785220172502138828.
To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis.
Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and manufactured according to the part of the most severe deformity. The drill template was placed on the corresponding vertebral surface. Pedicle screws were carefully inserted across the trajectory of the template. Postoperatively, the positions of the pedicle screws were evaluated by CT scan and graded for validation.
No spinal cord injury or nerve damage occurred. All patients had satisfactory outcomes. The abnormalities and the measures observed during operation were the same as those found in the preoperative period. The position of the pedicle screws was accurate, according to the postoperative X-ray and CT scan. The rate of scoliosis correction was 60%. Compared with controls, surgery time, blood loss and radiation were significantly lower.
With the application of multi-level template, the placement of pedicle screws shows high accuracy in scoliosis with shorter surgical time, less blood loss and less radiation exposure.
评估用于重度脊柱侧弯椎弓根螺钉置入的钻孔导向模板的准确性及效果。
纳入8例僵硬性脊柱侧弯患者,5例男性,3例女性,年龄9至23岁。对脊柱进行三维CT扫描并保存为DICOM文件类型。通过Mimics软件设计多级模板,并根据最严重畸形部位进行制作。将钻孔模板放置在相应椎体表面。沿模板轨迹小心置入椎弓根螺钉。术后,通过CT扫描评估椎弓根螺钉位置并分级以进行验证。
未发生脊髓损伤或神经损伤。所有患者预后良好。术中观察到的异常情况及措施与术前一致。根据术后X线和CT扫描,椎弓根螺钉位置准确。脊柱侧弯矫正率为60%。与对照组相比,手术时间、失血量和辐射量显著降低。
应用多级模板,椎弓根螺钉置入在脊柱侧弯中显示出高准确性,手术时间更短,失血量更少,辐射暴露更少。