Suppr超能文献

全髋关节置换术中金属对金属与金属对聚乙烯关节置换后金属离子浓度及植入物生存率的比较。

Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations.

作者信息

Dahlstrand Henrik, Stark André, Wick Marius C, Anissian Lucas, Hailer Nils P, Weiss Rüdiger J

机构信息

a Department of Molecular Medicine and Surgery, Section of Orthopaedics and Sports Medicine , Karolinska Institutet, Karolinska University Hospital , Stockholm.

b Department of Clinical Sciences , Danderyd Hospital, Karolinska Institutet , Stockholm.

出版信息

Acta Orthop. 2017 Oct;88(5):490-495. doi: 10.1080/17453674.2017.1350370. Epub 2017 Jul 12.

Abstract

Background and purpose - Large metal-on-metal (MoM) articulations are associated with metal wear and corrosion, leading to increased metal ion concentrations and unacceptable revision rates. There are few comparative studies of 28-mm MoM articulations with conventional metal-on-polyethylene (MoP) couplings. We present a long-term follow-up of a randomized controlled trial comparing MoM versus MoP 28-mm articulations, focused on metal ions and implant survival. Patients and methods - 85 patients with a mean age of 65 years at surgery were randomized to a MoM (Metasul) or a MoP (Protasul) bearing. After 16 years, 38 patients had died and 4 had undergone revision surgery. 13 patients were unavailable for clinical follow-up, leaving 30 patients (n = 14 MoM and n = 16 MoP) for analysis of metal ion concentrations and clinical outcome. Results - 15-year implant survival was similar in both groups (MoM 96% [95% CI 88-100] versus MoP 97% [95% CI 91-100]). The mean serum cobalt concentration was 4-fold higher in the MoM (1.5 μg/L) compared with the MoP cohort (0.4 μg/L, p < 0.001) and the mean chromium concentration was double in the MoM (2.2 μg/L) compared with the MoP cohort (1.0 μg/L, p = 0.05). Mean creatinine levels were similar in both groups (MoM 93 μmol/L versus MoP 92 μmol/L). Harris hip scores differed only marginally between the MoM and MoP cohorts. Interpretation - This is the longest follow-up of a randomized trial on 28-mm MoM articulations, and although implant survival in the 2 groups was similar, metal ion concentrations remained elevated in the MoM cohort even in the long term.

摘要

背景与目的——大型金属对金属(MoM)关节置换与金属磨损和腐蚀相关,会导致金属离子浓度升高以及不可接受的翻修率。关于28毫米MoM关节置换与传统金属对聚乙烯(MoP)关节置换的比较研究较少。我们对一项比较MoM与MoP 28毫米关节置换的随机对照试验进行了长期随访,重点关注金属离子和植入物生存率。

患者与方法——85例手术时平均年龄为65岁的患者被随机分为接受MoM(Metasul)或MoP(Protasul)关节置换。16年后,38例患者死亡,4例接受了翻修手术。13例患者无法进行临床随访,剩余30例患者(MoM组14例,MoP组16例)用于分析金属离子浓度和临床结果。

结果——两组15年植入物生存率相似(MoM组96%[95%CI 88 - 100],MoP组97%[95%CI 91 - 100])。MoM组的平均血清钴浓度(1.5μg/L)比MoP组(0.4μg/L,p < 0.001)高4倍,MoM组的平均铬浓度(2.2μg/L)比MoP组(1.0μg/L,p = 0.05)高1倍。两组的平均肌酐水平相似(MoM组93μmol/L,MoP组92μmol/L)。MoM组和MoP组的Harris髋关节评分仅略有差异。

解读——这是对28毫米MoM关节置换随机试验最长的随访,尽管两组的植入物生存率相似,但即使在长期,MoM组的金属离子浓度仍保持升高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7c56/5560210/7641ff3f1b7e/iort-88-490.F01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验