Suppr超能文献

低浓度过氧化氢(6%)经 LED 蓝光(450±10nm)和激光红外线(808±10nm)催化进行诊室牙齿美白治疗:随机临床试验 1 年随访。

Teeth bleaching with low concentrations of hydrogen peroxide (6%) and catalyzed by LED blue (450 ± 10 nm) and laser infrared (808 ± 10 nm) light for in-office treatment: Randomized clinical trial 1-year follow-up.

机构信息

Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile.

Universidad Andres Bello.

出版信息

J Esthet Restor Dent. 2017 Sep;29(5):339-345. doi: 10.1111/jerd.12318. Epub 2017 Jul 16.

Abstract

OBJECTIVES

The aim of this study was to evaluate color longevity after a year of in-office bleaching with gel (6% hydrogen peroxide HP, LED blue/laser infrared activation system) compared to a 35% control concentration in a split-mouth study model.

MATERIALS AND METHODS

Thirty-one patients were initially treated. The bleaching procedure with 6% or 35% gel HP was performed randomly in the upper half arcade of each patient. The color was measured at baseline and at 1 week, 1 month, and 1 year using the spectrophotometer Vita Easyshade, Vita Bleached, and Vita classical Shade guide organized by value. During the 1-year recall, the color was assessed before and after dental prophylaxis.

RESULTS

Only 27 patients were assessed in the 1-year recall. There was a significant difference in the ΔE between the two groups at all times assessed (P < .011). The ΔL, Δa, and Δb showed significant difference between both groups at all assessed times (P < .038). There was no significant difference between the ΔSGU at all times (P > .05) except for the Vita bleachedguide postprophylaxis comparison (P < .05).

CONCLUSION

The two compounds remained effective at 1 year. When objectively evaluated, color difference between groups was found, not seen when subjectively determined.

CLINICAL SIGNIFICANCE

A low concentration hydrogen peroxide bleaching agent can reach good clinical results at 1 year of follow-up.

摘要

目的

本研究旨在通过分口研究模型,评估凝胶(6%过氧化氢 HP、LED 蓝光/激光红外激活系统)诊室漂白 1 年后的颜色保持情况与 35%对照浓度相比的效果。

材料和方法

最初治疗了 31 名患者。患者上颌每半口随机进行 6%或 35%凝胶 HP 的漂白程序。使用分光光度计 Vita Easyshade、Vita Bleached 和 Vita 经典比色指南(按值组织)在基线、1 周、1 个月和 1 年时测量颜色。在 1 年的随访期间,在进行牙齿洁治前后评估颜色。

结果

只有 27 名患者在 1 年的随访中进行了评估。在所有评估时间,两组之间的ΔE 均存在显著差异(P<.011)。在所有评估时间,两组之间的 ΔL、Δa 和 Δb 均存在显著差异(P<.038)。在所有时间,ΔSGU 之间均无显著差异(P>.05),但洁治后 Vita Bleached 指南的比较除外(P<.05)。

结论

两种化合物在 1 年后仍保持有效。当客观评估时,发现组间存在颜色差异,而主观评估时则没有发现。

临床意义

低浓度过氧化氢漂白剂在 1 年的随访中可以达到良好的临床效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验