Suppr超能文献

基质重塑和小切口微透镜提取中的透镜厚度准确性:一年结果。

Stromal remodeling and lenticule thickness accuracy in small-incision lenticule extraction: One-year results.

机构信息

From the Department of Ophthalmology (Luft, Mursch-Edlmayr, Bolz) and the Ars Ophthalmica Study Center (Luft, Ring, Mursch-Edlmayr, Bolz), Kepler University Hospital, Linz, Austria; University Eye Hospital (Luft, Priglinger, Mayer, Kreutzer, Dirisamer), Ludwig-Maximilians-University, Munich, Germany.

From the Department of Ophthalmology (Luft, Mursch-Edlmayr, Bolz) and the Ars Ophthalmica Study Center (Luft, Ring, Mursch-Edlmayr, Bolz), Kepler University Hospital, Linz, Austria; University Eye Hospital (Luft, Priglinger, Mayer, Kreutzer, Dirisamer), Ludwig-Maximilians-University, Munich, Germany.

出版信息

J Cataract Refract Surg. 2017 Jun;43(6):812-818. doi: 10.1016/j.jcrs.2017.03.038.

Abstract

PURPOSE

To prospectively characterize the stromal thickness changes during the first year after myopic small-incision lenticule extraction using spectral-domain optical coherence tomography (SD-OCT).

SETTING

Department of Ophthalmology, Kepler University Hospital, Linz, Austria.

DESIGN

Prospective case series.

METHODS

This study evaluated eyes that had small-incision lenticule extraction to treat myopia or myopic astigmatism. A high-resolution SD-OCT system (RS 3000 Advance) in conjunction with a custom image-segmentation algorithm was applied to directly measure stromal thickness within the central 5.0 mm corneal zone. Measurements were obtained preoperatively and postoperatively at 1 day, 1 week, 6 weeks, 3 months, 6 months, and 1 year.

RESULTS

The study enrolled 42 eyes of 21 patients. The mean surgical refractive correction was -4.94 diopters ± 1.75 (SD). Postoperatively, the stromal thickness showed a significant decrease during the first 6 weeks, which amounted to a mean of 10.4 ± 6.3 μm at the apex (P < .001). Subsequently, the central stroma thickened by a mean of 8.8 ± 5.9 μm up until the 1-year follow-up (P < .001). One year postoperatively, the mean observed central stromal thickness reduction was 18.7 ± 5.7 μm smaller than the planned lenticule thickness. This difference was smallest 6 weeks postoperatively (mean 9.8 ± 7.8 μm).

CONCLUSIONS

Significant anatomic changes in the corneal stroma were detected during the first year after small-incision lenticule extraction. The achieved lenticule thickness was systematically lower than planned, and the mismatch was more pronounced with higher lenticule thickness. Refractive outcomes did not appear to be influenced by lenticule thickness accuracy.

摘要

目的

使用频域光学相干断层扫描(SD-OCT)前瞻性地描述近视小切口透镜取出术后第一年基质厚度的变化。

设置

奥地利林茨开普勒大学医院眼科。

设计

前瞻性病例系列。

方法

本研究评估了接受小切口透镜取出术治疗近视或近视散光的眼睛。高分辨率 SD-OCT 系统(RS 3000 Advance)与定制的图像分割算法相结合,用于直接测量中央 5.0mm 角膜区域内的基质厚度。术前和术后 1 天、1 周、6 周、3 个月、6 个月和 1 年进行测量。

结果

该研究纳入了 21 名患者的 42 只眼。平均手术矫正屈光度数为-4.94 屈光度±1.75(标准差)。术后前 6 周基质厚度明显下降,顶点处平均减少 10.4±6.3μm(P<0.001)。随后,中央基质厚度在 1 年随访时增加了 8.8±5.9μm(P<0.001)。术后 1 年,观察到的中央基质厚度平均减少了 18.7±5.7μm,比计划的透镜厚度小。这种差异在术后 6 周时最小(平均 9.8±7.8μm)。

结论

在小切口透镜取出术后的第一年,角膜基质发生了明显的解剖学变化。实际获得的透镜厚度系统地低于计划厚度,且与较高的透镜厚度相比,不匹配更为明显。屈光结果似乎不受透镜厚度准确性的影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验