无胰腺炎临床或超声检查证据的猫的特定猫胰腺脂肪酶浓度的生物学变异估计。

Estimates of biologic variation in specific feline pancreatic lipase concentrations in cats without clinical or ultrasonographic evidence of pancreatitis.

作者信息

Cohn-Urbach Margaret, Ruaux Craig G, Nemanic Sarah

机构信息

Department of Veterinary Clinical Sciences, Oregon State University, Corvallis, OR, USA.

出版信息

Vet Clin Pathol. 2017 Dec;46(4):615-619. doi: 10.1111/vcp.12528. Epub 2017 Jul 24.

Abstract

BACKGROUND

Serum concentrations of feline-specific pancreatic lipase are commonly used for diagnosis and monitoring of pancreatitis in cats, but little is known regarding biologic variation of this analyte.

OBJECTIVES

The purpose of the study was to determine biologic variation, index of individuality, and reference change values (RCV) for specific feline pancreatic lipase concentrations (Spec fPL) in apparently healthy cats.

METHODS

Four blood samples were collected prospectively from 12 apparently healthy cats at 2-week intervals. The Spec fPL was measured in all serum samples by a reference laboratory.

RESULTS

Intra-individual variation for Spec fPL was 33.5% (95% CI 27.1-43.8%); inter-individual variation was 99.9% (69.2-169.9%) and analytic variation was 7.3% (6.1-9.2%). Reciprocal index of individuality for Spec fPL was 2.9 (2.5-3.8), the 2-sided RCV was 95.1% (77.0-123.9%).

CONCLUSIONS

Due to high individuality, use of a population-based RI for Spec fPL may fail to detect clinically significant elevations in individual cats. The use of subject-based RIs for Spec fPL may have greater sensitivity for the detection of a change in pancreatic physiology in cats; however, this would require serial assessment of apparently healthy cats.

摘要

背景

猫特异性胰腺脂肪酶的血清浓度常用于猫胰腺炎的诊断和监测,但关于该分析物的生物学变异知之甚少。

目的

本研究的目的是确定健康猫中特异性猫胰腺脂肪酶浓度(Spec fPL)的生物学变异、个体指数和参考变化值(RCV)。

方法

前瞻性地从12只健康猫每隔2周采集4份血样。所有血清样本中的Spec fPL由一家参考实验室进行检测。

结果

Spec fPL的个体内变异为33.5%(95%可信区间27.1 - 43.8%);个体间变异为99.9%(69.2 - 169.9%),分析变异为7.3%(6.1 - 9.2%)。Spec fPL的个体指数倒数为2.9(2.5 - 3.8),双侧RCV为95.1%(77.0 - 123.9%)。

结论

由于个体差异大,使用基于群体的Spec fPL参考区间可能无法检测到个别猫临床上显著的升高。使用基于个体的Spec fPL参考区间可能对检测猫胰腺生理变化具有更高的敏感性;然而,这需要对健康猫进行连续评估。