Moradi Haghgoo Janet, Arabi Seyed Reza, Hosseinipanah Seyyed Mohammad, Solgi Ghasem, Rastegarfard Neda, Farhadian Maryam
Department of Periodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
Department of Anatomical Science, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran.
J Dent Res Dent Clin Dent Prospects. 2017 Spring;11(2):73-77. doi: 10.15171/joddd.2017.014. Epub 2017 Jun 21.
This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device.
本研究旨在比较采用不同方法获取的自体骨移植的活力,以确定就更多活细胞而言的最佳获取技术。在这项动物实验研究中,使用三种获取方法,包括手动器械(凿子)、旋转装置和压电手术,从10只兔子左右两侧下颌骨体外侧获取骨移植。每组收集20个骨样本,并使用MTS试剂盒评估其活力。使用方差分析(ANOVA)和事后 Tukey 检验等统计分析来评估组间的显著差异。单因素方差分析显示所有组之间存在显著差异(P = 0.000)。使用事后 Tukey 检验进行数据分析表明,手动器械和压电手术在细胞活力方面没有显著差异(P = 0.749),且两组的细胞活力均高于使用旋转器械的组(P = 0.000)。与使用旋转装置获取的骨碎片相比,使用手动器械和压电手术获取的自体骨移植具有更多活细胞。