Jiménez J S Estepa, Lagos M Díaz, Martinez-Ovalle S A
Universidad Nacional de Costa Rica (UNA), Avenida 1, Calle 9, Apartado Postal 86-3000, Heredia, Costa Rica.
Universidad Pedagógica y Tecnológica de Colombia, Boyacá, Colombia.
Comput Math Methods Med. 2017;2017:3621631. doi: 10.1155/2017/3621631. Epub 2017 Jul 10.
Different types the spectrum of photons were studied; they were emitted from the flattening filter of a LINAC Varian 2100 C/D that operates at 15 MV. The simplified geometry of the LINAC head was calculated using the MCNPX code based on the studies of the materials of the flattening filter, namely, SST, W, Pb, Fe, Ta, Al, and Cu. These materials were replaced in the flattening filter to calculate the photon spectra at the output of this device to obtain the spectrum that makes an impact with the patient. The different spectra obtained were analyzed and compared to the emission from the original spectra configuration of the LINAC, which uses material W. In the study, different combinations of materials were considered in order to establish differences between the use of different materials and the original material, with the objective of establishing advantages and disadvantages from a clinical standpoint.