Suppr超能文献

牙本质生物改性剂对一种简化酸蚀冲洗粘结剂与牙本质即刻和长期粘结强度的影响。

Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin.

作者信息

Singh Payal, Nagpal Rajni, Singh Udai Pratap

机构信息

Department of Conservative Dentistry and Endodontics, Kothiwal Dental College and Research Center, Moradabad, UP, India.

出版信息

Restor Dent Endod. 2017 Aug;42(3):188-199. doi: 10.5395/rde.2017.42.3.188. Epub 2017 Jul 12.

Abstract

OBJECTIVES

This study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin.

MATERIALS AND METHODS

Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups ( = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA), and Tukey's test.

RESULTS

At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only ( = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall.

CONCLUSIONS

Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

摘要

目的

本研究评估牙本质生物改性剂对一种简化酸蚀冲洗粘结剂与牙本质即刻和长期粘结强度的影响。

材料与方法

在120颗拔除的人类磨牙上制备平坦的冠部牙本质表面。根据5种不同的表面预处理方法将牙齿随机分为5组(每组n = 24):不进行预处理(对照组);1M碳二亚胺(EDC);0.1%表没食子儿茶素-3-没食子酸酯(EGCG);2%米诺环素(MI);10%抗坏血酸钠(SA)。表面预处理后,应用粘结剂(Adper Single Bond 2 [SB],3M ESPE)。将复合树脂填入透明塑料管(直径2.5 mm)中,放置在粘结的牙本质表面上。每组中,10个样本在24小时(即刻)进行剪切粘结强度(SBS)评估,其余10个样本在6个月后(延迟)进行测试。此外,每组取4个样本进行扫描电子显微镜分析,以观察树脂-牙本质界面。数据采用Shapiro-Wilk W检验、双向方差分析(ANOVA)和Tukey检验进行统计学分析。

结果

在24小时时,所有表面预处理组的SBS与对照组相当,仅EDC组和SA组之间存在显著差异(P = 0.009)。储存6个月后,EDC、EGCG和MI预处理可保持树脂-牙本质粘结强度,无显著下降。

结论

除SA外,所有牙本质生物改性剂对牙本质进行预处理,在6个月的储存期内均可显著保持树脂-牙本质粘结,且不会对所测试的酸蚀冲洗粘结剂的即刻粘结强度产生负面影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2e96/5553018/50951d369d3f/rde-42-188-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验