采用兆赫兹扫频光源的内镜前视光学相干断层扫描与血管造影术。
Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source.
作者信息
Liang Kaicheng, Ahsen Osman O, Wang Zhao, Lee Hsiang-Chieh, Liang Wenxuan, Potsaid Benjamin M, Tsai Tsung-Han, Giacomelli Michael G, Jayaraman Vijaysekhar, Mashimo Hiroshi, Li Xingde, Fujimoto James G
出版信息
Opt Lett. 2017 Aug 15;42(16):3193-3196. doi: 10.1364/OL.42.003193.
Endoscopic optical coherence tomography (OCT) instruments are mostly side viewing and rely on at least one proximal scan, thus limiting accuracy of volumetric imaging and en face visualization. Previous forward-viewing OCT devices had limited axial scan speeds. We report a forward-viewing fiber scanning 3D-OCT probe with 900 μm field of view and 5 μm transverse resolution, imaging at 1 MHz axial scan rate in the human gastrointestinal tract. The probe is 3.3 mm diameter and 20 mm rigid length, thus enabling passage through the endoscopic channel. The scanner has 1.8 kHz resonant frequency, and each volumetric acquisition takes 0.17 s with 2 volumes/s display. 3D-OCT and angiography imaging of the colon was performed during surveillance colonoscopy.
内镜光学相干断层扫描(OCT)设备大多是侧视的,并且依赖至少一次近端扫描,因此限制了容积成像和正面可视化的准确性。以前的前视OCT设备轴向扫描速度有限。我们报告了一种前视光纤扫描三维OCT探头,其视野为900μm,横向分辨率为5μm,可在人体胃肠道中以1MHz的轴向扫描速率成像。该探头直径为3.3mm,刚性长度为20mm,因此能够通过内镜通道。该扫描仪的共振频率为1.8kHz,每次容积采集需要0.17秒,显示速度为每秒2幅容积图像。在监测结肠镜检查期间对结肠进行了三维OCT和血管造影成像。