Ascalone V, Catalani P, Dal Bo' L, Deschamps N, Guinebault P
J Chromatogr. 1987 Feb 20;414(1):101-8. doi: 10.1016/0378-4347(87)80028-2.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of alpidem and its metabolites in human plasma. The method involved a single extraction of the parent drug and metabolites into diethyl ether from alkalinized plasma, evaporation of the organic solution and chromatography of the extracts on a C18 column coupled to a fluorimetric detector. An internal standard was used for the quantitative determination of the compounds. The method was selective for alpidem and three of its metabolites and has a limit of detection of less than 1 ng ml-1 for all the compounds. Since the chromatographic run took more than 20 min, the chromatographic process was fully automated and performed overnight.