Balsam Paweł, Lodziński Piotr, Tymińska Agata, Ozierański Krzysztof, Januszkiewicz Łukasz, Główczyńska Renata, Wesołowska Katarzyna, Peller Michał, Pietrzak Radosław, Książczyk Tomasz, Borodzicz Sonia, Kołtowski Łukasz, Borkowski Mariusz, Werner Bożena, Opolski Grzegorz, Grabowski Marcin
1st Chair and Department of Cardiology, Medical University of Warsaw, Public Central Teaching Hospital in Warsaw, Banacha 1a, 02-097 Warsaw, Poland.
Cardiol J. 2018;25(1):52-59. doi: 10.5603/CJ.a2017.0102. Epub 2017 Aug 25.
Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system.
An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device.
The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations.
This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).
如今,研究人员面临的主要挑战是开发新技术,以帮助改善心血管疾病(CVD)的诊断,从而降低医疗成本并提高患者的生活质量。本研究旨在展示使用Nuubo®心电图(nECG)系统对不同临床情况下的CVD患者进行基于生物医学衬衫的心电图(ECG)监测的效用。
在心脏病学(成人和儿科)及心脏康复病房开展了一项由研究者发起的多中心前瞻性观察性研究。在以下四组独立患者中使用生物医学衬衫进行ECG监测:1)30例肺静脉隔离(PVI)术后患者,2)30例接受心脏再同步治疗(CRT)的患者,3)120例心肌梗死后心脏康复期间的患者,4)40例电生理研究前患有室上性心动过速(SVT)的儿科患者。所有研究组均获得了机构审查委员会的批准。生物医学衬衫通过集成在衣服上的纺织电极捕捉心电图信号。该软件允许对诸如ECG、心率、心律失常检测算法等数据进行可视化和分析,并且身体的相对位置由电子设备捕捉。
nECG系统的主要优点是在日常活动期间进行连续ECG监测、ECG记录质量高,以及由于穿着衬衫时足够舒适而确保了适当的依从性。仅有少数研究考察了可穿戴系统,尤其是在儿科人群中。
本研究已在ClinicalTrials.gov注册:标识符NCT03068169。(《心脏病学杂志》2018年;25卷,第1期:52 - 59页)