Biomed Res Int. 2017;2017:4701481. doi: 10.1155/2017/4701481. Epub 2017 Aug 23.
Nonfocused low-intensity ultrasound is generally believed to be less efficacious than High-Intensity Focused Ultrasound (HIFU) at body fat reduction; nevertheless, this technology has already been widely used clinically for body contouring purposes. This study aimed to evaluate the efficacy and safety of this new technology by applying 1 MHz nonfocused ultrasound at 3 W/cm to the outer-thigh region of rat models. Ultrasonography measurement demonstrated an average reduction of 0.5 mm of subcutaneous fat thickness that persisted for at least three days after treatment. Biochemical analysis quantified a significant increase in lipid levels, specifically triglyceride, high-density lipoprotein, and total cholesterol. These two findings of subcutaneous fat reduction and plasma lipid increase showed a positive correlation. No evidence of adverse events or complications was observed after the treatment. This study validated nonfocused low-intensity ultrasound as an effective and safe method for body fat reduction, especially with repetitive treatment. However, the concurrent increase in plasma lipid level will require further investigation to determine this technology's long-term impact, if any, on health.
非聚焦低强度超声通常被认为在减脂方面不如高强度聚焦超声(HIFU)有效;然而,这项技术已经在临床上广泛用于身体塑形。本研究旨在通过应用 1MHz 非聚焦超声,在 3W/cm 下对大鼠模型的大腿外侧区域进行评估,以验证这项新技术的疗效和安全性。超声测量显示,治疗后至少三天内,皮下脂肪厚度平均减少了 0.5mm。生化分析定量显示,血脂水平,特别是甘油三酯、高密度脂蛋白和总胆固醇显著升高。这两项皮下脂肪减少和血浆脂质增加的发现呈正相关。治疗后未观察到不良反应或并发症的证据。本研究验证了非聚焦低强度超声作为一种有效和安全的减脂方法,特别是重复治疗。然而,血浆脂质水平的同时升高需要进一步研究,以确定该技术对健康的长期影响(如果有的话)。