Suppr超能文献

通过计算机断层扫描测量,转子间骨折髓内钉固定患者术后臀中肌横截面积减小。

Decreased postoperative gluteus medius muscle cross-sectional area measured by computed tomography scan in patients with intertrochanteric fractures nailing.

作者信息

Noda Mitsuaki, Saegusa Yasuhiro, Takahashi Masayasu, Takada Yuma, Fujita Masahiro, Shinohara Issei

机构信息

Department of Orthopedics, Konan Hospital, Kobe City, Japan.

出版信息

J Orthop Surg (Hong Kong). 2017 Sep-Dec;25(3):2309499017727943. doi: 10.1177/2309499017727943.

Abstract

BACKGROUND

In patients with femoral intertrochanteric fractures treated by cephalomedullary (CM) nailing, abduction force reportedly decreased by 25-30% during the postoperative follow-up period. The purpose of the current study is to evaluate the cross-sectional area (CSA) and adipose tissue ratio (ATR) of the gluteus medius muscle on the postoperative computed tomography (CT) view, expecting this graphic study will support clinical results.

MATERIALS AND METHODS

A total of 27 patients with femoral intertrochanteric fractures treated by CM femoral nail implants completed the study. The mean age at osteosynthesis was 83 years (range: 72-94 years). The mean postoperative follow-up period was 23 months. The three CT axial slice views were defined as slices A, B, and C corresponding to proximal, midway, and distal part of gluteus medius, respectively. The CSA and ATR were assessed bilaterally.

RESULTS

The mean and standard deviation of CSA values (mm) between the nonoperated/ operated side were as follows: slice A: 2225.8 ± 621.2/1984.5 ± 425.8; slice B: 2145.1 ± 538.3/1854.9 ± 383.9; and slice C: 1711.0 ± 459.0/1434.5 ± 396.9 ( p < 0.01 in slices A, B, and C). The mean and standard deviation of ATR values (%) from the nonoperative/ operative side were as follows: slice A: 2.8 ± 1.7/5.2 ± 3.5; slice B: 2.7 ± 1.9/4.6 ± 3.2; and slice C: 3.6 ± 3.0/4.8 ± 3.2 ( p < 0.01 in slices A and B and p < 0.05 in slice C).

CONCLUSION

Our image findings documented that gluteus medius is significantly changed in CSA and ATR. The damage possibly triggers decrease in muscular strength of hip abduction in the postoperative follow-up period. This measurement is objective, and needed no patient's endurance and cooperation.

摘要

背景

据报道,在接受髓内钉固定治疗的股骨转子间骨折患者中,术后随访期间外展力下降了25%至30%。本研究的目的是评估术后计算机断层扫描(CT)图像上臀中肌的横截面积(CSA)和脂肪组织比率(ATR),期望这项影像学研究能够支持临床结果。

材料与方法

共有27例接受股骨髓内钉植入治疗的股骨转子间骨折患者完成了本研究。骨合成时的平均年龄为83岁(范围:72至94岁)。术后平均随访期为23个月。三个CT轴位切片视图分别定义为对应于臀中肌近端、中部和远端的切片A、B和C。双侧评估CSA和ATR。

结果

非手术侧/手术侧CSA值(mm)的平均值和标准差如下:切片A:2225.8±621.2/1984.5±425.8;切片B:2145.1±538.3/1854.9±383.9;切片C:1711.0±459.0/1434.5±396.9(切片A、B和C中p<0.01)。非手术侧/手术侧ATR值(%)的平均值和标准差如下:切片A:2.8±1.7/5.2±3.5;切片B:2.7±1.9/4.6±3.2;切片C:3.6±3.0/4.8±3.2(切片A和B中p<0.01,切片C中p<0.05)。

结论

我们的影像学研究结果表明,臀中肌的CSA和ATR有显著变化。这种损伤可能会导致术后随访期间髋关节外展肌力下降。这种测量是客观的,不需要患者的耐力和配合。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验