Abstract

PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4-5 for imaging a single organ such as the brain or heart. The world's first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET.

摘要

PET 被广泛认为是一种非侵入性的活体人体生理学、代谢和分子途径研究的最敏感技术。然而,由于其光子缺乏的特性,PET 的应用仍然受到包括信噪比低、成像时间长以及对辐射剂量的担忧等因素的限制。有两个发展方向有可能显著提高 PET 的有效灵敏度。首先,通过增加几何覆盖范围来覆盖整个身体,可以将全身成像的灵敏度提高约 40 倍,或者将单个器官(如大脑或心脏)的成像灵敏度提高约 4-5 倍。目前正在建造世界上第一台全身 PET/CT 扫描仪,以展示这种灵敏度的阶跃变化如何影响 PET 在临床研究和患者护理中的应用方式。其次,时间分辨率的未来前景有望显著提高,这可能会带来进一步的有效灵敏度提升。当与全身 PET 结合使用时,与现有最先进的系统相比,这可能会产生超过两个数量级的整体灵敏度提升。本文讨论了增加身体覆盖范围的好处,描述了我们开发第一代全身 PET/CT 扫描仪的努力,讨论了全身 PET 的选定应用领域,并预测了飞行时间 PET 进一步改进的影响。

相似文献

5
First Human Imaging Studies with the EXPLORER Total-Body PET Scanner.首例全身 EXPLORER PET 扫描仪人体成像研究。
J Nucl Med. 2019 Mar;60(3):299-303. doi: 10.2967/jnumed.119.226498. Epub 2019 Feb 7.
6
Integrated PET/MR.正电子发射断层扫描/磁共振成像(PET/MR)
J Magn Reson Imaging. 2014 Feb;39(2):243-58. doi: 10.1002/jmri.24523. Epub 2013 Dec 12.
9
New cardiac cameras: single-photon emission CT and PET.新型心脏相机:单光子发射 CT 和 PET。
Semin Nucl Med. 2014 Jul;44(4):232-51. doi: 10.1053/j.semnuclmed.2014.04.003.

引用本文的文献

本文引用的文献

2
Forward to the Past: The Case for Quantitative PET Imaging.穿越时空:正电子发射断层显像术的定量研究。
J Nucl Med. 2017 Jul;58(7):1019-1024. doi: 10.2967/jnumed.116.188029. Epub 2017 May 18.
6
Metabolic Imaging of Glutamine in Cancer.癌症中谷氨酰胺的代谢成像
J Nucl Med. 2017 Apr;58(4):533-537. doi: 10.2967/jnumed.116.182345. Epub 2017 Feb 23.
9
Parallax error in long-axial field-of-view PET scanners-a simulation study.长轴视野PET扫描仪中的视差误差——一项模拟研究
Phys Med Biol. 2016 Jul 21;61(14):5443-5455. doi: 10.1088/0031-9155/61/14/5443. Epub 2016 Jul 1.