Suppr超能文献

种植体修复体的不匹配及其对临床结果的影响。定义、评估及文献系统评价

Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature.

作者信息

Katsoulis Joannis, Takeichi Takuro, Sol Gaviria Ana, Peter Lukas, Katsoulis Konstantinos

出版信息

Eur J Oral Implantol. 2017;10 Suppl 1:121-138.

Abstract

BACKGROUND AND AIM

Compromised fit between the contact surfaces of screw-retained implant-supported fixed dentures (IFDs) is thought to create uncontrolled strains in the prosthetic components and peri-implant tissues, thus evoking biological and technical complications such as bone loss, screw loosening, component fractures and, at worst, loss of implants or prostheses. The aim of this systematic review was to evaluate the impact of marginal misfit on the clinical outcomes of IFDs, and to elucidate definition and assessment methods for passive fit.

MATERIALS AND METHODS

A systematic review of the literature was conducted with a PICO question: "For partially or complete edentulous subjects with screw-retained IFDs, does the marginal misfit at the implant-prosthesis interfaces have an impact on the clinical outcomes?". A literature search was performed electronically in PubMed (MEDLINE) with the help of Boolean operators to combine key words, and by hand search in relevant journals. English written in vivo studies published before August 31, 2016 that reported on both clinical outcome and related implant prosthesis misfit (gap, strains, torque) were selected using predetermined inclusion criteria.

RESULTS

The initial search yielded 2626 records. After screening and a subsequent filtering process, five human and five animal studies were included in the descriptive analysis. The selected studies used different methods to assess misfit (linear distortion, vertical gap, strains, screw torque). While two human studies evaluated the biological response and technical complications prospectively over 6 and 12 months, the animal studies had an observation period < 12 weeks. Four human studies analysed retrospectively the 3 to 32 years' outcomes. Screw-related complications were observed, but biological sequelae could not be confirmed. Although the animal studies had different designs, bone adaptation and implant displacement was found in histological analyses. Due to the small number of studies and the heterogenic designs and misfit assessment methods, no meta-analysis of the data could be performed.

CONCLUSIONS

The current literature provides insufficient evidence as to the effect of misfit at the prosthesis-implant interface on clinical outcomes of screw-retained implant-supported fixed dentures. Marginal gaps and static strains due to screw tightening were not found to have negative effects on initial osseointegration or peri-implant bone stability over time. Based on two clinical studies, the risk for technical screw-related complications was slightly higher. While the degree of tolerable misfit remains a matter of debate, the present data do not imply that clinicians neglect good fit, but aim to achieve the least misfit possible. Conflict of interest statement: The authors declare no conflict of interest. The review was conducted as part of the 2016 Foundation of Oral Rehabilitation Consensus Conference on "Prosthetic Protocols in Implant-based Oral Rehabilitation".

摘要

背景与目的

螺钉固位种植体支持的固定义齿(IFD)的接触表面贴合度欠佳,被认为会在修复部件和种植体周围组织中产生无法控制的应变,从而引发诸如骨质流失、螺钉松动、部件骨折等生物学和技术并发症,最严重的情况是种植体或修复体丧失。本系统评价的目的是评估边缘不贴合对IFD临床结局的影响,并阐明被动贴合的定义和评估方法。

材料与方法

采用PICO问题对文献进行系统评价:“对于采用螺钉固位IFD的部分或全部牙列缺失患者,种植体 - 修复体界面的边缘不贴合是否会对临床结局产生影响?”。借助布尔运算符在PubMed(MEDLINE)中进行电子文献检索以组合关键词,并通过手工检索相关期刊。使用预定的纳入标准,选择2016年8月31日前发表的、报道了临床结局以及相关种植体修复体不贴合情况(间隙、应变、扭矩)的英文体内研究。

结果

初步检索得到2626条记录。经过筛选和后续过滤过程,五项人体研究和五项动物研究纳入描述性分析。所选研究使用不同方法评估不贴合情况(线性变形、垂直间隙、应变、螺钉扭矩)。两项人体研究前瞻性评估了6个月和12个月期间的生物学反应和技术并发症,而动物研究的观察期<12周。四项人体研究回顾性分析了3至32年的结局。观察到与螺钉相关的并发症,但生物学后遗症无法得到证实。尽管动物研究设计不同,但在组织学分析中发现了骨适应性和种植体移位。由于研究数量少、设计和不贴合评估方法存在异质性,无法对数据进行荟萃分析。

结论

目前的文献对于修复体 - 种植体界面不贴合对螺钉固位种植体支持的固定义齿临床结局的影响提供的证据不足。未发现因螺钉拧紧导致的边缘间隙和静态应变对初始骨结合或种植体周围骨稳定性随时间产生负面影响。基于两项临床研究,与螺钉相关的技术并发症风险略高。虽然可耐受的不贴合程度仍存在争议,但目前的数据并不意味着临床医生可以忽视良好的贴合度,而是旨在尽可能减少不贴合情况。利益冲突声明:作者声明无利益冲突。本评价是作为2016年口腔修复基础共识会议“基于种植体的口腔修复中的修复方案”的一部分进行的。