伴有静脉 - 静脉肺辅助的保护性通气治疗呼吸衰竭:一项关于急性低氧性呼吸衰竭患者体外二氧化碳清除的多中心随机对照试验方案

pRotective vEntilation with veno-venouS lung assisT in respiratory failure: A protocol for a multicentre randomised controlled trial of extracorporeal carbon dioxide removal in patients with acute hypoxaemic respiratory failure.

作者信息

McNamee J J, Gillies M A, Barrett N A, Agus A M, Beale R, Bentley A, Bodenham A, Brett S J, Brodie D, Finney S J, Gordon A J, Griffiths M, Harrison D, Jackson C, McDowell C, McNally C, Perkins G D, Tunnicliffe W, Vuylsteke A, Walsh T S, Wise M P, Young D, McAuley D F

机构信息

Regional Intensive Care Unit, Royal Victoria Hospital, Belfast Health and Social Care Trust, Belfast, UK.

Centre for Experimental Medicine, School of Medicine, Dentistry and Biomedical Sciences, Wellcome Wolfson Institute for Experimental Medicine, Queens University Belfast, Belfast, UK.

出版信息

J Intensive Care Soc. 2017 May;18(2):159-169. doi: 10.1177/1751143716681035. Epub 2016 Dec 19.

Abstract

One of the few interventions to demonstrate improved outcomes for acute hypoxaemic respiratory failure is reducing tidal volumes when using mechanical ventilation, often termed lung protective ventilation. Veno-venous extracorporeal carbon dioxide removal (vv-ECCOR) can facilitate reducing tidal volumes. pRotective vEntilation with veno-venouS lung assisT (REST) is a randomised, allocation concealed, controlled, open, multicentre pragmatic trial to determine the clinical and cost-effectiveness of lower tidal volume mechanical ventilation facilitated by vv-ECCOR in patients with acute hypoxaemic respiratory failure. Patients requiring intubation and mechanical ventilation for acute hypoxaemic respiratory failure will be randomly allocated to receive either vv-ECCOR and lower tidal volume mechanical ventilation or standard care with stratification by recruitment centre. There is a need for a large randomised controlled trial to establish whether vv-ECCOR in acute hypoxaemic respiratory failure can allow the use of a more protective lung ventilation strategy and is associated with improved patient outcomes.

摘要

在少数已证明可改善急性低氧性呼吸衰竭预后的干预措施中,机械通气时降低潮气量是其中之一,这通常被称为肺保护性通气。静脉-静脉体外二氧化碳清除(vv-ECCOR)有助于降低潮气量。静脉-静脉肺辅助保护性通气(REST)是一项随机、分配隐藏、对照、开放、多中心实用性试验,旨在确定vv-ECCOR辅助下的低潮气量机械通气对急性低氧性呼吸衰竭患者的临床疗效和成本效益。因急性低氧性呼吸衰竭需要插管和机械通气的患者将被随机分配接受vv-ECCOR和低潮气量机械通气,或按招募中心分层接受标准治疗。需要进行一项大型随机对照试验,以确定急性低氧性呼吸衰竭患者使用vv-ECCOR是否能采用更具保护性的肺通气策略,并改善患者预后。

相似文献

引用本文的文献

9
Extra-corporeal membrane oxygenation for severe respiratory failure in the UK.英国用于严重呼吸衰竭的体外膜肺氧合
J Intensive Care Soc. 2020 Aug;21(3):247-255. doi: 10.1177/1751143719870082. Epub 2019 Sep 5.

本文引用的文献

1
Ultra-protective ventilation and hypoxemia.超保护性通气与低氧血症
Crit Care. 2016 May 12;20(1):130. doi: 10.1186/s13054-016-1310-9.
2
Acute respiratory distress syndrome.急性呼吸窘迫综合征
Lancet. 2016 Nov 12;388(10058):2416-2430. doi: 10.1016/S0140-6736(16)00578-X. Epub 2016 Apr 28.
7
Ventilator-induced lung injury.呼吸机相关性肺损伤
N Engl J Med. 2013 Nov 28;369(22):2126-36. doi: 10.1056/NEJMra1208707.
10
Prone positioning in severe acute respiratory distress syndrome.俯卧位通气治疗严重急性呼吸窘迫综合征。
N Engl J Med. 2013 Jun 6;368(23):2159-68. doi: 10.1056/NEJMoa1214103. Epub 2013 May 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验