Suppr超能文献

散射和像差对带状角膜病变视力的影响。

Effect of Scattering and Aberrations on Visual Acuity for Band Keratopathy.

作者信息

Kamiya Kazutaka, Kobashi Hidenaga, Takahashi Masahide, Shoji Nobuyuki, Shimizu Kimiya

机构信息

1School of Allied Health Sciences, Kitasato University, Kanagawa, Japan 2Department of Ophthalmology, Kitasato University, Kanagawa, Japan 3Department of Ophthalmology, Sanno Hospital, Tokyo, Japan *

出版信息

Optom Vis Sci. 2017 Nov;94(11):1009-1014. doi: 10.1097/OPX.0000000000001134.

Abstract

SIGNIFICANCE

The progressive accumulation of the calcification may deteriorate corneal transparency, especially in the interpalpebral area, and subsequent visual performance for patients with band keratopathy. However, the detailed quantitative analysis of light scattering or higher-order aberrations on visual performance for these patients so far has not been elucidated.

PURPOSE

The aim of this study was to assess the relationship of intraocular forward scattering, corneal backward scattering, and corneal higher-order aberrations with visual acuity in eyes with band keratopathy.

METHODS

This prospective study comprised 27 eyes of 27 consecutive patients who were diagnosed as having band keratopathy and age-matched 27 eyes of 27 healthy subjects. We quantitatively assessed objective scattering index using the double-pass instrument (Optical Quality Analysis System II; Visiometrics, Terrassa, Spain), corneal densitometry using the Scheimpflug rotating camera (Pentacam HR; Oculus, Wetzlar, Germany), and corneal higher-order aberrations using the Hartmann-Shack aberrometry (KR-9000; Topcon, Tokyo, Japan).

RESULTS

The mean objective scattering index, corneal densitometry, corneal higher-order aberrations, and logarithm of the minimal angle of resolution (logMAR) visual acuity in eyes with band keratopathy were 5.14 ± 3.11, 36.42 ± 10.55 gray-scale units, 0.33 ± 0.10 μm, and 0.03 ± 0.11 logMAR, respectively. These parameters were significantly larger in the band keratopathy group than in those in the control group (Mann-Whitney U test, P < .001). We found significant correlations of visual acuity with the objective scattering index (Spearman correlation coefficient, r = 0.465, P = .015), but no significant association with the corneal densitometry (r = 0.082, P = .683) or with corneal higher-order aberrations (r = -0.073, P = .718), in eyes having band keratopathy.

CONCLUSIONS

Intraocular forward scattering, corneal backward scattering, and corneal higher-order aberrations in eyes with band keratopathy were significantly higher than those in normal eyes. Visual acuity was significantly correlated with intraocular forward scattering, but not with corneal backward scattering or corneal aberrations in the band keratopathy group, suggesting that intraocular forward scattering plays a vital role in visual performance in eyes with band keratopathy.

摘要

意义

钙化的进行性积累可能会降低角膜透明度,尤其是在睑裂区,进而影响带状角膜病变患者的视觉表现。然而,迄今为止,尚未对这些患者视觉表现的光散射或高阶像差进行详细的定量分析。

目的

本研究旨在评估带状角膜病变患者眼内前向散射、角膜后向散射和角膜高阶像差与视力之间的关系。

方法

这项前瞻性研究纳入了27例连续诊断为带状角膜病变患者的27只眼,以及年龄匹配的27名健康受试者的27只眼。我们使用双程仪器(光学质量分析系统II;Visiometrics,西班牙特拉萨)定量评估客观散射指数,使用Scheimpflug旋转相机(Pentacam HR;德国韦茨拉尔奥culus)进行角膜密度测量,使用Hartmann-Shack像差仪(KR-9000;日本东京Topcon)测量角膜高阶像差。

结果

带状角膜病变患者眼内的平均客观散射指数、角膜密度测量值、角膜高阶像差和最小分辨角对数(logMAR)视力分别为5.14±3.11、36.42±10.55灰度单位、0.33±0.10μm和0.03±0.11 logMAR。这些参数在带状角膜病变组中显著高于对照组(Mann-Whitney U检验,P <.001)。我们发现,在带状角膜病变患者眼中,视力与客观散射指数显著相关(Spearman相关系数,r = 0.465,P =.015),但与角膜密度测量值(r = 0.082,P =.683)或角膜高阶像差(r = -0.073,P =.718)无显著关联。

结论

带状角膜病变患者眼内的前向散射、角膜后向散射和角膜高阶像差显著高于正常眼。在带状角膜病变组中,视力与眼内前向散射显著相关,但与角膜后向散射或角膜像差无关,这表明眼内前向散射在带状角膜病变患者的视觉表现中起着至关重要的作用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验