基于铕(III)螯合物微球的侧向流免疫层析试纸条用于快速定量检测乙型肝炎核心抗原抗体。

Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen.

机构信息

Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, P.R. China.

Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, Guangzhou, 510515, P.R. China.

出版信息

Sci Rep. 2017 Oct 26;7(1):14093. doi: 10.1038/s41598-017-14427-4.

Abstract

Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral flow immunoassay (LFIA) method integrated with Eu (III) chelate microparticles to quantitatively determine anti-HBc concentrations in serum. This assay is based on a direct competitive immunoassay performed on lateral flow test strips with an assay time of 15 min. The Eu (III) chelate microparticle-based LFIA assay could quantitatively detect anti-HBc levels with a limit of detection of 0.31 IU mL, and exhibited a wide linear range (0.63-640 IU mL). The intra- and inter-assay coefficients of variation for anti-HBc were both less than 10% and a satisfactory dilution test and accuracy were demonstrated. There were no statistically significant differences in sensitivity or specificity in serum samples between the Eu (III) chelate microparticle-based LFIA strips and the Abbott Architect kit. A simple, rapid and effective quantitative detection of anti-HBc was possible using the Eu (III) chelate microparticle-based LFIA strips. The strips will provide diagnostic value for clinical application.

摘要

乙型肝炎核心抗体定量(抗-HBc)检测在评估慢性乙型肝炎感染的治疗效果和优化抗病毒治疗方面可能发挥重要作用。本研究基于侧向流动免疫分析(LFIA)方法,开发了一种简单快速的荧光即时检测方法,集成了铕(III)螯合物微球,用于定量检测血清中的抗-HBc 浓度。该检测方法基于侧向流动试纸上的直接竞争免疫测定,测定时间为 15 分钟。基于铕(III)螯合物微球的 LFIA 检测方法可以定量检测抗-HBc 水平,检测限为 0.31IU/mL,线性范围较宽(0.63-640IU/mL)。抗-HBc 的批内和批间变异系数均小于 10%,稀释试验和准确度令人满意。Eu(III)螯合物微球 LFIA 条与 Abbott Architect 试剂盒在血清样本中的灵敏度或特异性均无统计学差异。使用 Eu(III)螯合物微球 LFIA 条可以简单、快速、有效地定量检测抗-HBc。该条将为临床应用提供诊断价值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0320/5658374/0e32ea600777/41598_2017_14427_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验