Suppr超能文献

脑脊液的T映射:3T与7T对比

T mapping of cerebrospinal fluid: 3 T versus 7 T.

作者信息

Spijkerman Jolanda M, Petersen Esben T, Hendrikse Jeroen, Luijten Peter, Zwanenburg Jaco J M

机构信息

Department of Radiology, University Medical Center Utrecht, HP E 01.132, P.O.Box 85500, 3508 GA, Utrecht, The Netherlands.

Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, 2650, Hvidovre, Denmark.

出版信息

MAGMA. 2018 Jun;31(3):415-424. doi: 10.1007/s10334-017-0659-3. Epub 2017 Nov 6.

Abstract

OBJECT

Cerebrospinal fluid (CSF) T mapping can potentially be used to investigate CSF composition. A previously proposed CSF T -mapping method reported a T difference between peripheral and ventricular CSF, and suggested that this reflected different CSF compositions. We studied the performance of this method at 7 T and evaluated the influence of partial volume and B and B inhomogeneity.

MATERIALS AND METHODS

T -preparation-based CSF T -mapping was performed in seven healthy volunteers at 7 and 3 T, and was compared with a single echo spin-echo sequence with various echo times. The influence of partial volume was assessed by our analyzing the longest echo times only. B and B maps were acquired. B and B dependency of the sequences was tested with a phantom.

RESULTS

T was shorter at 7 T compared with 3 T. At 3 T, but not at 7 T, peripheral T was significantly shorter than ventricular T . Partial volume contributed to this T difference, but could not fully explain it. B and B inhomogeneity had only a very limited effect. T did not depend on the voxel size, probably because of the used method to select of the regions of interest.

CONCLUSION

CSF T mapping is feasible at 7 T. The shorter peripheral T is likely a combined effect of partial volume and CSF composition.

摘要

目的

脑脊液(CSF)T 映射可潜在地用于研究脑脊液成分。先前提出的一种脑脊液T 映射方法报告了外周脑脊液和脑室脑脊液之间的T 差异,并表明这反映了不同的脑脊液成分。我们研究了该方法在7T时的性能,并评估了部分容积以及B 和B 不均匀性的影响。

材料与方法

在7名健康志愿者中于7T和3T进行基于T 准备的脑脊液T 映射,并与具有不同回波时间的单回波自旋回波序列进行比较。仅通过分析最长回波时间来评估部分容积的影响。采集了B 和B 图。使用体模测试了序列对B 和B 的依赖性。

结果

与3T相比,7T时的T 更短。在3T时,外周T 显著短于脑室T ,但在7T时并非如此。部分容积导致了这种T 差异,但不能完全解释它。B 和B 不均匀性的影响非常有限。T 不依赖于体素大小,可能是由于所使用的选择感兴趣区域的方法。

结论

脑脊液T 映射在7T时是可行的。外周T 较短可能是部分容积和脑脊液成分共同作用的结果。