基于 CT 的 Crowe Ⅲ型髋关节发育不良患者骨盆骨量评估:对采用高位髋关节中心技术指导髋臼假体放置的指导意义。

Computed Tomographic Evaluation of Bone Stock in Patients With Crowe Type III Developmental Dysplasia of the Hip: Implications for Guiding Acetabular Component Placement Using the High Hip Center Technique.

机构信息

Department of Orthopaedic Surgery, The First Hospital of Jilin University, Changchun, Jilin, People's Republic of China.

出版信息

J Arthroplasty. 2018 Mar;33(3):915-918. doi: 10.1016/j.arth.2017.10.021. Epub 2017 Oct 24.

Abstract

BACKGROUND

We evaluated acetabular cup coverage (CC) and rim contact (RC) to evaluate the bone stock above the acetabulum for guiding acetabular component placement using the high hip center technique in patients with Crowe type III developmental dysplasia of the hip.

METHODS

Using hip computed tomography and image processing software, pelvises were reconstructed digitally in 20 hips with Crowe type III developmental dysplasia of the hip. Mimicked cup was placed with anteversion angles of 0° (group I), 5° (group II), and 10° (group III) respectively. In each group, the cup was placed at the anatomical hip center at first, and then the cup was moved up to 40 mm vertically about the native rotation center with an increment of 2.5 mm at each step. CC and RC were calculated and documented with each movement.

RESULTS

CC was 65.87%, 67.77%, and 68.98% for group I, group II, and group III at the native rotation center, and increased progressively to 86.45%, 85.85%, and 84.71% at 25 mm above. RC was 49.17%, 50.25%, and 51.92% for group I, group II, and group III at the native rotation center, and increased progressively to 86.87%, 86.39%, and 84.94% at 22.5 mm above. CC and RC were positively correlated, despite the different anteversion angles (r = 0.687 at 0°, 0.683 at 5°, and 0.645 at 10°; P < .001).

CONCLUSION

Computed tomography analysis and computer stimulation demonstrate that it is feasible to use high hip center technique in Crowe type III hips.

摘要

背景

我们评估了髋臼杯覆盖率(CC)和边缘接触(RC),以评估髋臼上方的骨质情况,从而指导使用高位髋关节中心技术在 Crowe Ⅲ型发育性髋关节发育不良患者中进行髋臼部件放置。

方法

使用髋关节 CT 和图像处理软件,对 20 例 Crowe Ⅲ型发育性髋关节发育不良的髋关节进行数字骨盆重建。模拟髋臼杯分别以 0°(I 组)、5°(II 组)和 10°(III 组)的前倾角放置。在每组中,首先将髋臼杯放置在解剖学髋关节中心,然后将髋臼杯向上移动 40mm 垂直于原始旋转中心,每次移动增加 2.5mm。在每次移动时计算并记录 CC 和 RC。

结果

在原始旋转中心,I 组、II 组和 III 组的 CC 分别为 65.87%、67.77%和 68.98%,逐渐增加至 25mm 以上的 86.45%、85.85%和 84.71%。在原始旋转中心,I 组、II 组和 III 组的 RC 分别为 49.17%、50.25%和 51.92%,逐渐增加至 22.5mm 以上的 86.87%、86.39%和 84.94%。尽管前倾角不同,但 CC 和 RC 呈正相关(0°时 r=0.687,5°时 r=0.683,10°时 r=0.645;P<.001)。

结论

CT 分析和计算机模拟表明,在 Crowe Ⅲ型髋关节中使用高位髋关节中心技术是可行的。