Brindle Richard A, Ebaugh David, Milner Clare E
J Sport Rehabil. 2018 May 1;27(3). doi: 10.1123/jsr.2017-0177. Epub 2018 Jun 6.
Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a "break" test, the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower.
To determine intrarater reliability and construct validity of a hip abductor eccentric strength test.
Intrarater reliability and construct validity study.
Twenty healthy adults (26 [6] y; 1.66 [0.06] m; 62.2 [8.0] kg) made 2 visits to the laboratory at least 1 week apart.
During the hip abductor eccentric strength test, a handheld dynamometer recorded peak force and time to peak force, and limb position was recorded via a motion capture system. Intrarater reliability was determined using intraclass correlation, SEM, and minimal detectable difference. Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a 1-sample t test.
The hip abductor eccentric strength test had substantial intrarater reliability (intraclass correlation = .88; 95% confidence interval, .65-.95), SEM of 0.9 %BWh, and a minimal detectable difference of 2.5 %BWh. Construct validity was established as peak force occurred 2.1 (0.6) seconds (range: 0.7-3.7 s) after the start of the lowering phase of the test (P ≤ .001).
The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.
侧卧髋关节外展肌力量测试常用于评估肌肉力量。在“突破”测试中,测试者施加足够的力将肢体放低到桌子上,同时患者进行抵抗。假定峰值力在腿部下降时出现,从而代表参与者的离心肌肉力量。然而,尚不清楚峰值力是在腿部开始下降之前还是之后出现。
确定髋关节外展肌离心力量测试的评估者内信度和结构效度。
评估者内信度和结构效度研究。
20名健康成年人(年龄26[6]岁;身高1.66[0.06]米;体重62.2[8.0]千克),至少间隔1周两次前往实验室。
在髋关节外展肌离心力量测试期间,手持式测力计记录峰值力和达到峰值力的时间,肢体位置通过运动捕捉系统记录。使用组内相关系数、标准误和最小可检测差异来确定评估者内信度。通过使用单样本t检验确定峰值力是否在下降阶段开始后出现来评估结构效度。
髋关节外展肌离心力量测试具有较高的评估者内信度(组内相关系数=0.88;95%置信区间,0.65 - 0.95),标准误为0.9%BWh,最小可检测差异为2.5%BWh。结构效度得以确立,因为峰值力在测试下降阶段开始后2.1(0.6)秒出现(范围:0.7 - 3.7秒)(P≤0.001)。
髋关节外展肌离心力量测试是一种有效且可靠的离心肌肉力量测量方法。该测试可在临床上用于评估离心肌肉力量随时间的变化。