Suppr超能文献

髋外展肌离心力量测试的测试者内信度及结构效度

Intratester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

作者信息

Brindle Richard A, Ebaugh David, Milner Clare E

出版信息

J Sport Rehabil. 2018 May 1;27(3). doi: 10.1123/jsr.2017-0177. Epub 2018 Jun 6.

Abstract

CONTEXT

Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a "break" test, the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower.

OBJECTIVES

To determine intrarater reliability and construct validity of a hip abductor eccentric strength test.

DESIGN

Intrarater reliability and construct validity study.

PARTICIPANTS

Twenty healthy adults (26 [6] y; 1.66 [0.06] m; 62.2 [8.0] kg) made 2 visits to the laboratory at least 1 week apart.

MAIN OUTCOME MEASURES

During the hip abductor eccentric strength test, a handheld dynamometer recorded peak force and time to peak force, and limb position was recorded via a motion capture system. Intrarater reliability was determined using intraclass correlation, SEM, and minimal detectable difference. Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a 1-sample t test.

RESULTS

The hip abductor eccentric strength test had substantial intrarater reliability (intraclass correlation = .88; 95% confidence interval, .65-.95), SEM of 0.9 %BWh, and a minimal detectable difference of 2.5 %BWh. Construct validity was established as peak force occurred 2.1 (0.6) seconds (range: 0.7-3.7 s) after the start of the lowering phase of the test (P ≤ .001).

CONCLUSION

The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

摘要

背景

侧卧髋关节外展肌力量测试常用于评估肌肉力量。在“突破”测试中,测试者施加足够的力将肢体放低到桌子上,同时患者进行抵抗。假定峰值力在腿部下降时出现,从而代表参与者的离心肌肉力量。然而,尚不清楚峰值力是在腿部开始下降之前还是之后出现。

目的

确定髋关节外展肌离心力量测试的评估者内信度和结构效度。

设计

评估者内信度和结构效度研究。

参与者

20名健康成年人(年龄26[6]岁;身高1.66[0.06]米;体重62.2[8.0]千克),至少间隔1周两次前往实验室。

主要观察指标

在髋关节外展肌离心力量测试期间,手持式测力计记录峰值力和达到峰值力的时间,肢体位置通过运动捕捉系统记录。使用组内相关系数、标准误和最小可检测差异来确定评估者内信度。通过使用单样本t检验确定峰值力是否在下降阶段开始后出现来评估结构效度。

结果

髋关节外展肌离心力量测试具有较高的评估者内信度(组内相关系数=0.88;95%置信区间,0.65 - 0.95),标准误为0.9%BWh,最小可检测差异为2.5%BWh。结构效度得以确立,因为峰值力在测试下降阶段开始后2.1(0.6)秒出现(范围:0.7 - 3.7秒)(P≤0.001)。

结论

髋关节外展肌离心力量测试是一种有效且可靠的离心肌肉力量测量方法。该测试可在临床上用于评估离心肌肉力量随时间的变化。

相似文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验