不同下颌覆盖义齿Locator 附着体脱位力与种植体末端倾斜角度的关系:一项体外研究。

Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study.

机构信息

Department of Removable Prosthodontics, University of Mansoura, Faculty of Dentistry, Eldakahlia, Egypt.

Department of Maxillofacial Prosthodontics, University of Cairo, National Cancer Institute, Cairo, Egypt.

出版信息

J Prosthodont. 2019 Feb;28(2):e666-e674. doi: 10.1111/jopr.12710. Epub 2017 Nov 16.

Abstract

PURPOSE

To evaluate the effect of distal implant inclination on axial and nonaxial retentive forces of different Locator attachments used to retain mandibular overdentures.

MATERIALS AND METHODS

Four duplicate mandibular edentulous acrylic models received 2 implants in the canine areas with 0°, 5°, 10°, and 20° distal inclinations. Experimental overdentures were connected to the implants with Locator extra light retention (Le), Locator light retention (Ll), and Locator medium retention (Lm). For the 20° model, extended range Locator extra-light retention (Lee) and Locator medium retention (Lem) were used. Axial and nonaxial (anterior, posterior, lateral) retentive forces were measured initially and after 540 cycles of denture insertion and removal. Three-way mixed ANOVA was used to analyze axial and nonaxial retentive forces RESULTS: After wear simulation, 20° angulation showed the highest axial retention for Le and Ll while 5° showed the highest retention for Lm; 0° and 5° showed the highest anterior and posterior retention for Lm; 20° showed the highest lateral retention for Le and Ll. For all implant inclinations, Lm showed the highest axial and nonaxial retention, and Le and Lee showed the lowest retention for 10° and 20° inclined implants, respectively.

CONCLUSIONS

Axial and nonaxial retention of Locator attachments for implant-retained overdentures are significantly affected by the degree of distal implant inclination and the type of nylon inserts. Lm is recommended to retain overdentures when implants have 5° or 10° distal inclination, and Le and Ll are recommended with 20° inclination to maintain high axial and nonaxial retention after wear.

摘要

目的

评估不同Locator 附着体用于保留下颌覆盖义齿时,种植体远中倾斜角度对轴向和非轴向固位力的影响。

材料与方法

四个相同的下颌无牙颌丙烯酸模型,在犬齿区植入两颗种植体,分别为 0°、5°、10°和 20°远中倾斜角。实验性覆盖义齿通过 Locator 超轻保持(Le)、Locator 轻保持(Ll)和 Locator 中保持(Lm)与种植体相连。对于 20°模型,使用扩展范围 Locator 超轻保持(Lee)和 Locator 中保持(Lem)。分别在初始状态和义齿插入及取出 540 次循环后测量轴向和非轴向(前、后、侧)固位力。采用三因素混合方差分析比较轴向和非轴向固位力。

结果

磨损模拟后,Le 和 Ll 在 20°倾斜角时表现出最高的轴向固位力,而 Lm 在 5°时表现出最高的保持力;Lm 在 0°和 5°时表现出最高的前、后向固位力;Le 和 Ll 在 20°时表现出最高的侧向固位力。对于所有种植体倾斜角度,Lm 表现出最高的轴向和非轴向固位力,而 Le 和 Lee 则在 10°和 20°倾斜种植体时表现出最低的固位力。

结论

Locator 附着体用于种植体支持覆盖义齿的轴向和非轴向固位力受种植体远中倾斜角度和尼龙插入物类型的显著影响。当种植体有 5°或 10°远中倾斜时,推荐使用 Lm 保留覆盖义齿,当种植体有 20°倾斜时,推荐使用 Le 和 Ll 以保持高的轴向和非轴向固位力。