Suppr超能文献

不同程度近中种植体倾斜对采用球帽附着体固位的下颌双种植覆盖义齿固位和稳定性的影响:一项体外研究

Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In Vitro Study.

作者信息

ELsyad Moustafa Abdou, Abo Hatem Omar Emhemed, Shawky Ahmad Fathalla, Emera Radwa Mohsen Kamal

出版信息

Int J Oral Maxillofac Implants. 2018 March/April;33(2):259–268. doi: 10.11607/jomi.5791. Epub 2017 Oct 13.

Abstract

PURPOSE

To evaluate the effect of different degrees of mesial implant inclinations on the retention and stability of two-implant mandibular overdentures retained with stud attachments.

MATERIALS AND METHODS

Four experimental mandibular acrylic models were constructed. Two laboratory implants were inserted in the canine areas of each model with the following degrees of mesial inclinations: 0, 5, 10, and 20 degrees. Experimental overdentures were connected to the implants with Locator extra-light retention (Le), Locator light retention (Ll), and Locator medium retention (Lm). Vertical (retention) and oblique (stability) dislodging forces (anterior, posterior, and lateral) were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention).

RESULTS

The final retention was not significantly affected by small (5 degrees) and large (20 degrees) implant inclinations, but decreased with a moderate (10 degrees) inclination. For a small implant inclination (5 degrees), Lm showed the highest final retention/stability and Le showed the lowest, while for moderate and large inclinations (10 and 20 degrees), Le showed the highest final retention/stability and Lm showed the lowest. Vertical dislodging recorded the highest final stability, and lateral dislodgment recorded the lowest stability.

CONCLUSION

Within the limitations of this in vitro study, only moderate implant angulation (10 degrees) negatively affects the final retention and stability of Locator-retained overdentures. Locator medium retention for small angulation (5 degrees) and Locator extra-light retention for moderate (10 degrees) and large (20 degrees) angulations are recommended to maintain high retention and stability after 540 cycles of denture insertion and removal.

摘要

目的

评估不同程度的种植体近中倾斜对采用球帽附着体固位的下颌双种植体覆盖义齿固位和稳定性的影响。

材料与方法

制作四个实验性下颌丙烯酸树脂模型。在每个模型的尖牙区植入两枚实验室种植体,使其具有以下不同程度的近中倾斜度:0°、5°、10°和20°。实验性覆盖义齿通过Locator超轻型固位体(Le)、Locator轻型固位体(Ll)和Locator中型固位体(Lm)与种植体相连。在研究开始时(初始固位)以及义齿插入和取出540次循环后(最终固位),测量垂直(固位)和斜向(稳定性)脱位力(前向、后向和侧向)。

结果

较小(5°)和较大(20°)的种植体倾斜度对最终固位没有显著影响,但随着中等程度(10°)的倾斜度,最终固位降低。对于较小的种植体倾斜度(5°),Lm显示出最高的最终固位/稳定性,而Le显示出最低的;对于中等和较大倾斜度(10°和20°),Le显示出最高的最终固位/稳定性,而Lm显示出最低的。垂直脱位记录的最终稳定性最高,侧向脱位记录的稳定性最低。

结论

在本体外研究的局限性内,只有中等程度的种植体角度(10°)会对Locator固位的覆盖义齿的最终固位和稳定性产生负面影响。对于小角度(5°)推荐使用Locator中型固位体,对于中等(10°)和大角度(20°)推荐使用Locator超轻型固位体以在义齿插入和取出540次循环后保持高固位和稳定性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验