ELsyad Moustafa Abdou, Agha Nora Nory, Habib Ahmed Ali
Int J Oral Maxillofac Implants. 2016 Sep-Oct;31(5):1040-8. doi: 10.11607/jomi.4544.
The aim of this study was to evaluate and compare the retention and stability of mandibular implant overdentures using different types of resilient attachments.
Two implant analogs were inserted in the canine areas of an acrylic edentulous mandibular model. A metal-reinforced experimental overdenture was constructed and connected to the implant analogs (on two occasions) using either resilient telescopic or Locator attachments. Locators were divided into three subgroups according to the degree of retention of the male nylon insert: Locator extra-light retention (blue insert), Locator light retention (pink insert), and Locator medium retention (transparent insert). Vertical and oblique (anterior, posterior, and lateral) dislodging forces were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention).
For all dislodging forces, Locator medium recorded the highest initial and final retention. Telescopic attachments recorded the lowest retention during vertical and anterior dislodging, and Locator extra-light recorded the lowest retention during lateral and posterior dislodging. For all types of Locator attachments, anterior dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For the telescopic attachment, posterior dislodgment recorded the highest initial and final retention, and anterior dislodging recorded the lowest retention.
After repeated denture insertions and removals, the highest retention and stability were recorded with Locator medium followed by Locator light. The lowest retention was recorded with resilient telescopic attachment, and the lowest stability was recorded with Locator extra-light.
本研究旨在评估和比较使用不同类型弹性附着体的下颌种植覆盖义齿的固位和稳定性。
在丙烯酸树脂无牙下颌模型的尖牙区植入两个种植体代型。制作一个金属增强的实验性覆盖义齿,并使用弹性套筒冠或Locator附着体(分两次)将其与种植体代型连接。Locator根据阳性尼龙插入件的固位程度分为三个亚组:Locator超轻固位(蓝色插入件)、Locator轻固位(粉色插入件)和Locator中固位(透明插入件)。在研究开始时(初始固位)以及义齿插入和取出540次循环后(最终固位)测量垂直和斜向(前、后和侧向)脱位力。
对于所有脱位力,Locator中固位记录的初始和最终固位最高。套筒冠附着体在垂直和向前脱位时记录的固位最低,Locator超轻固位在侧向和向后脱位时记录的固位最低。对于所有类型的Locator附着体,向前脱位记录的初始和最终固位最高,侧向脱位记录的固位最低。对于套筒冠附着体,向后脱位记录的初始和最终固位最高,向前脱位记录的固位最低。
在义齿反复插入和取出后,Locator中固位记录的固位和稳定性最高,其次是Locator轻固位。弹性套筒冠附着体记录的固位最低,Locator超轻固位记录的稳定性最低。