Suppr超能文献

MRI 评估 BI-RADS 4 类乳腺钼靶微钙化的恶性程度。

MRI for the assessment of malignancy in BI-RADS 4 mammographic microcalcifications.

机构信息

Department of Pharmaceutical Chemistry, University of Vienna, Vienna, Austria.

Department of Biomedical Imaging and Image-guided Therapy, Vienna General Hospital (AKH), Medical University of Vienna, Vienna, Austria.

出版信息

PLoS One. 2017 Nov 30;12(11):e0188679. doi: 10.1371/journal.pone.0188679. eCollection 2017.

Abstract

PURPOSE

Assess the performance of breast MRI to diagnose breast cancer in BI-RADS 4 microcalcifications detected by mammography.

MATERIALS AND METHODS

This retrospective, IRB-approved study included 248 consecutive contrast-enhanced breast MRI (1.5T, protocol in accordance with EUSOBI recommendations) performed to further diagnose BI-RADS 4 microcalcifications detected at mammography during a 3-year period. Standard of reference had to be established by histopathology. Routine consensus reading results by two radiologists were dichotomized as positive or negative and compared with the reference standard (benign vs malignant) to calculate diagnostic parameters.

RESULTS

There were 107 malignant and 141 benign microcalcifications. Malignancy rates were 18.3% (23/126 BI-RADS 4a), 41.7% (25/60 BI-RADS 4b) and 95% (59/62 BI-RADS 4c). There were 103 true-positive, 116 true-negative, 25 false-positive, and 4 false-negative (one invasive cancer, three DCIS; 2 BI-RADS 4c, 1 BI-RADS 4b on mammography) breast MRI findings, effecting a sensitivity, specificity, PPV, and NPV of 96.3% (95%-CI 90.7-99.0%), 82.3% (95%-CI 75.0-88.2%), 80.5% (95%-CI 72.5-87.0%) and 96.7% (95%-CI 91.7-99.1%), respectively.

CONCLUSION

MRI is an accurate tool to further diagnose BI-RADS 4a and 4b microcalcifications and may be helpful to avoid unnecessary biopsies in BI-RADS 4a and 4b lesions. BI-RADS 4c microcalcifications should be biopsied irrespective of MRI findings.

摘要

目的

评估乳腺 MRI 诊断乳腺 X 线摄影 BI-RADS 4 微钙化的性能。

材料与方法

本回顾性研究经机构审查委员会批准,纳入 248 例连续接受对比增强乳腺 MRI(1.5T,方案符合 EUSOBI 建议)检查的患者,这些患者在 3 年内因乳腺 X 线摄影发现 BI-RADS 4 微钙化而进一步接受诊断。参考标准必须通过组织病理学建立。两位放射科医生的常规共识读片结果分为阳性或阴性,并与参考标准(良性与恶性)进行比较,以计算诊断参数。

结果

共发现 107 个恶性微钙化和 141 个良性微钙化。恶性率分别为 18.3%(23/126 BI-RADS 4a)、41.7%(25/60 BI-RADS 4b)和 95%(59/62 BI-RADS 4c)。有 103 个真阳性、116 个真阴性、25 个假阳性和 4 个假阴性(1 例浸润性癌,3 例 DCIS;乳腺 X 线摄影为 2 个 BI-RADS 4c、1 个 BI-RADS 4b)的乳腺 MRI 表现,其灵敏度、特异性、PPV 和 NPV 分别为 96.3%(95%CI 90.7-99.0%)、82.3%(95%CI 75.0-88.2%)、80.5%(95%CI 72.5-87.0%)和 96.7%(95%CI 91.7-99.1%)。

结论

MRI 是进一步诊断乳腺 X 线摄影 BI-RADS 4a 和 4b 微钙化的准确工具,可能有助于避免对 BI-RADS 4a 和 4b 病变进行不必要的活检。BI-RADS 4c 微钙化无论 MRI 结果如何都应进行活检。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bb09/5708819/fd95d81f790a/pone.0188679.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验