Suppr超能文献

采用新生儿高血细胞比容值血液中的血浆筛查低血糖症。

Screening for hypoglycemia with plasma in neonatal blood of high hematocrit value.

作者信息

Kaplan M, Blondheim O, Alon I, Eylath U, Trestian S, Eidelman A I

机构信息

Department of Neonatology, Shaare Zedek Medical Center, Jerusalem, Israel.

出版信息

Crit Care Med. 1989 Mar;17(3):279-82. doi: 10.1097/00003246-198903000-00016.

Abstract

A model utilizing human umbilical cord blood was used to screen for hypoglycemia in a simulated neonatal situation. The aims of the study were to assess the effect of increasing Hct concentration on Dextrostix readings, and to determine whether plasma samples, in contrast to conventional whole blood samples, were acceptable for Dextrostix determinations in selected cases. Dextrostix readings were determined on 65 whole blood samples of varying Hct, and on plasma specimens, 48 of which were paired with whole blood samples. The results were compared with plasma true glucose values. Plasma Dextrostix readings correlated well with true glucose values throughout the entire Hct range (r = .94, slope = 1.16). Whole blood Dextrostix readings, on the other hand, were Hct-dependent and, with increasing Hct values, became falsely low. As a result, a Hct values greater than 70%, whole blood Dextrostix readings were less than 50% of the true glucose value (r = .94, slope = 0.45). Plasma Dextrostix determinations may offer an accurate means of screening for neonatal hypoglycemia in asymptomatic infants with high Hct, pending laboratory glucose results.

摘要

在模拟新生儿情况下,使用一种利用人类脐带血的模型来筛查低血糖。本研究的目的是评估血细胞比容(Hct)浓度增加对葡萄糖试纸(Dextrostix)读数的影响,并确定在某些情况下,与传统全血样本相比,血浆样本是否可用于葡萄糖试纸测定。对65份不同Hct的全血样本以及48份与全血样本配对的血浆样本进行了葡萄糖试纸读数测定。将结果与血浆真实葡萄糖值进行比较。在整个Hct范围内,血浆葡萄糖试纸读数与真实葡萄糖值相关性良好(r = 0.94,斜率 = 1.16)。另一方面,全血葡萄糖试纸读数依赖于Hct,并且随着Hct值的增加,读数会错误地降低。因此,当Hct值大于70%时,全血葡萄糖试纸读数不到真实葡萄糖值的50%(r = 0.94,斜率 = 0.45)。在等待实验室血糖结果期间,血浆葡萄糖试纸测定可能为筛查Hct高的无症状婴儿的新生儿低血糖提供一种准确的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验