Suppr超能文献

刷牙对 5 种大块充填型树脂复合材料光泽保持和表面粗糙度的影响。

Effect of tooth brushing on gloss retention and surface roughness of five bulk-fill resin composites.

机构信息

Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.

Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.

出版信息

J Esthet Restor Dent. 2018 Jan;30(1):59-69. doi: 10.1111/jerd.12350. Epub 2017 Dec 5.

Abstract

OBJECTIVES

To determine the effects of tooth brushing on five bulk-fill resin based composites (RBCs).

METHOD

Ten samples of Filtek Supreme Enamel (control), Filtek One Bulk Fill, Tetric EvoCeram Bulk Fill, SonicFill 2, SDR flow+, and Admira Fusion X-tra were light cured for 20 seconds using the Valo Grand curing light. After 24 hours storage in air at 37°C, specimens were brushed in a random order using Colgate OpticWhite dentifrice and a soft toothbrush. Surface gloss was measured prior to brushing, after 5,000, 10,000 and 15,000 back and forth brushing cycles. Surface roughness was measured after 15,000 brushing cycles using atomic force microscopy (AFM) and selected scanning electron microscope (SEM) images were taken. The data was examined using ANOVA and pair-wise comparisons using Scheffe's post-hoc multiple comparison tests (α = 0.05).

RESULTS

Surface gloss decreased and the surface roughness increased after brushing. Two-way ANOVA showed that both the RBC and the number of brushing cycles had a significant negative effect on the gloss. One-way ANOVA showed that the RBC had a significant effect on the roughness after 15,000 brushing cycles. For both gloss and roughness, brushing had the least effect on the nano-filled control and nano-filled bulk-fill RBC, and the greatest negative effect on Admira Fusion X-tra. The SEM images provided visual agreement. There was an excellent linear correlation (R  = 0.98) between the logarithm of the gloss and roughness.

CONCLUSION

After brushing, the bulk-fill RBCs were all rougher than the control nano-filled RBC. The nano-filled bulk-fill RBC was the least affected by brushing.

CLINICAL SIGNIFICANCE

Bulk-fill RBCs lose their gloss faster and become rougher than the nanofilled conventional RBC, Filtek Supreme Ultra. The nanofilled bulk-fill RBC was the least affected by tooth brushing.

摘要

目的

研究牙刷牙刷对五种块状充填树脂基复合材料(RBC)的影响。

方法

采用 Valo Grand 光固化灯对 Filtek Supreme Enamel(对照组)、Filtek One Bulk Fill、Tetric EvoCeram Bulk Fill、SonicFill 2、SDR flow+和 Admira Fusion X-tra 各 10 个样本进行 20 秒的光固化。在 37°C 的空气中储存 24 小时后,以随机顺序使用 Colgate OpticWhite 牙膏和软毛牙刷刷牙。在刷牙前、刷牙后 5000 次、10000 次和 15000 次来回刷牙循环后测量表面光泽度。使用原子力显微镜(AFM)测量 15000 次刷牙循环后的表面粗糙度,并拍摄选定的扫描电子显微镜(SEM)图像。使用方差分析和 Scheffe 事后多重比较检验(α=0.05)对数据进行检验。

结果

刷牙后表面光泽度降低,表面粗糙度增加。双向方差分析表明,RBC 和刷牙次数都对光泽度有显著的负面影响。单向方差分析表明,在经过 15000 次刷牙循环后,RBC 对粗糙度有显著影响。对于光泽度和粗糙度,与纳米填充对照组和纳米填充块状填充 RBC 相比,刷牙的影响最小,对 Admira Fusion X-tra 的负面影响最大。SEM 图像提供了视觉上的一致性。光泽度和粗糙度之间存在极好的线性相关性(R=0.98)。

结论

刷牙后,块状充填 RBC 均比纳米填充对照组更粗糙。纳米填充块状填充 RBC 受刷牙影响最小。

临床意义

块状充填 RBC 比纳米填充传统 RBC(Filtek Supreme Ultra)更快失去光泽并变得更粗糙。纳米填充块状填充 RBC 受刷牙的影响最小。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验