Suppr超能文献

热疗质量保证指南。

Hyperthermia quality assurance guidelines.

作者信息

Shrivastava P, Luk K, Oleson J, Dewhirst M, Pajak T, Paliwal B, Perez C, Sapareto S, Saylor T, Steeves R

机构信息

Hyperthermia Physics Center, Allegheny-Singer Research Institute, Pittsburgh, PA 15212-9986.

出版信息

Int J Radiat Oncol Biol Phys. 1989 Mar;16(3):571-87. doi: 10.1016/0360-3016(89)90473-2.

Abstract

These Hyperthermia Quality Assurance guidelines are a result of a joint workshop of the Hyperthermia Committee of the American College of Radiology and the Hyperthermia Physics Center, which is the national quality assurance program under Contract No. N01-CM-37512 with the National Cancer Institute. Hyperthermia technology presently lacks the kind of standardization in equipment, treatment procedures, patient monitoring, and treatment documentation available in radiotherapy. Therefore, preventing unacceptable variability in treatment data demands a strong commitment to in-house quality control procedures and to centralized quality assurance reviews in cooperative multi-institutional trials. This paper presents a set of test procedures necessary to ensure proper operation of equipment, suggests a frequency for such tests, and also includes guidelines on quality control procedures to be used during treatment to improve the safety, effectiveness, and reproducibility of hyperthermia treatments. A set of forms are presented to indicate the minimum data, albeit incomplete, that must be collected for acceptable documentation of treatment. These guidelines should be valuable not only to the new entrants in the field but also to those participating in multi-institutional cooperative hyperthermia trials. They have been approved by the Hyperthermia Committees of American College of Radiology, American Society for Therapeutic Radiology and Oncology, Radiation Therapy Oncology Group and the American Association of Physicists in Medicine.

摘要

这些热疗质量保证指南是美国放射学会热疗委员会和热疗物理中心联合研讨会的成果,热疗物理中心是根据与美国国立癌症研究所签订的第N01-CM-37512号合同开展的国家质量保证项目。目前,热疗技术在设备、治疗程序、患者监测和治疗记录方面缺乏放射治疗中现有的那种标准化。因此,要防止治疗数据出现不可接受的差异,就需要坚定致力于内部质量控制程序以及合作性多机构试验中的集中质量保证审查。本文介绍了确保设备正常运行所需的一组测试程序,建议了此类测试的频率,还包括治疗期间使用的质量控制程序指南,以提高热疗治疗的安全性、有效性和可重复性。文中给出了一组表格,以表明为可接受的治疗记录必须收集的最少数据,尽管这些数据并不完整。这些指南不仅对该领域的新进入者有价值,对参与多机构合作热疗试验的人员也有价值。它们已获得美国放射学会热疗委员会、美国放射治疗及肿瘤学会、放射治疗肿瘤学组和美国医学物理学家协会的批准。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验