A 83-year-old woman with a single-chamber pacemaker implanted 15 years earlier was brought to the ED due to symptomatic bradycardia. ECG continuous monitoring allowed the diagnosis of atrial fibrillation with complete atrioventricular block in the setting of a complete failure to capture. The differing timing cycles of pacing outputs can confirm that sensing is preserved in the absence of a pacemaker programmer.
一位 83 岁女性,15 年前植入单腔起搏器,因有症状的心动过缓被送往 ED。心电图连续监测提示心房颤动伴完全性房室传导阻滞,且完全失夺获。起搏输出的不同计时周期可确认在没有起搏器程控仪的情况下保持了感知功能。