Suppr超能文献

锥形束计算机断层扫描图像的过滤和横截面厚度对近端龋检测的影响。

Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries.

作者信息

Abdinian Mehrdad, Nazeri Rahman, Ghaiour Marzieh

机构信息

Assistant Professor, Dental Implants Research Center, Department of Oral and Maxillofacial Radiology, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

Postgraduate Student, Department of Research, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

出版信息

J Dent (Tehran). 2017 Jul;14(4):223-230.

Abstract

OBJECTIVES

When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the "as low as reasonably achievable" (ALARA) principle. The aim of this study was to determine the effect of filtration and thickness of CBCT cross-sections on detection of proximal caries.

MATERIALS AND METHODS

In this in-vitro study, 100 teeth were placed in the dental sockets of a dry skull, and were fixed in normal proximal contacts. CBCT images were taken and were evaluated by two observers on the panoramic view at 1-, 3- and 5-mm-thick cross-sections, with the use of filtrations 0, 1 and 2. Afterwards, the samples were sectioned and underwent a histological evaluation. McNemar's test was used to compare the findings on CBCT images and histological evaluation. Receiver operating characteristic (ROC) curves and logistic regression were used to evaluate the diagnostic accuracy of different cross-sections.

RESULTS

The maximum AZ-value was achieved at 3-mm thickness/filtration 2. However, the differences between 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1 were not significant (P=0.728 and 0.868, respectively). The minimum AZ-value was achieved at 5-mm thickness/filtration 0.

CONCLUSIONS

Although CBCT is not sufficiently effective in detecting caries, the best cross-sections for detection of proximal caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1.

摘要

目的

当患者基于治疗计划获得锥形束计算机断层扫描(CBCT)图像时,根据“合理可行尽量低”(ALARA)原则,可使用这些图像评估龋齿,无需进行新的X光片检查。本研究的目的是确定CBCT横截面的过滤和厚度对邻面龋齿检测的影响。

材料与方法

在这项体外研究中,将100颗牙齿置于干燥颅骨的牙槽窝中,并固定在正常邻面接触状态。拍摄CBCT图像,由两名观察者在全景视图下对1毫米、3毫米和5毫米厚的横截面进行评估,使用的过滤值分别为0、1和2。之后,将样本切片并进行组织学评估。采用McNemar检验比较CBCT图像和组织学评估的结果。使用受试者工作特征(ROC)曲线和逻辑回归评估不同横截面的诊断准确性。

结果

在3毫米厚度/过滤值2时获得最大AZ值。然而,1毫米厚度/过滤值2和1毫米厚度/过滤值1之间的差异不显著(P值分别为0.728和0.868)。在5毫米厚度/过滤值0时获得最小AZ值。

结论

尽管CBCT在检测龋齿方面效果不够理想,但检测邻面龋齿的最佳横截面为3毫米厚度/过滤值2、1毫米厚度/过滤值2和1毫米厚度/过滤值1。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5bf1/5745226/e122bffc8b0a/JOD-14-223-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验