School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States; Jiangsu Academy of Agricultural Sciences, Nanjing 210014, People's Republic of China.
School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States.
Biosens Bioelectron. 2018 May 1;104:39-44. doi: 10.1016/j.bios.2017.12.029. Epub 2017 Dec 21.
A novel sandwich immunoassay based immunochromatographic test strip (ICTS) has been developed for simultaneously measuring both butyrylcholinesterase (BChE) activity and the total amount of BChE (including inhibited and active enzyme) from 70 μLpost-exposure human plasma sample. The principle of this method is based on the BChE monoclonal antibody (MAb) capable of acting as both capture antibody and detection antibody. The BChE MAb which was immobilized on the test line was able to recognize both organophosphorus BChE adducts (OP-BChE) and BChE and provided equal binding affinity, permitting detection of the total enzyme amount in post-exposure human plasma samples. The formed immunocomplexes on the test line can further be excised from the test-strip for subsequent off-line measurement of BChE activity using the Ellman assay. Therefore, dual biomarkers of BChE activity and phosphorylation (OP-BChE) will be obtained simultaneously. The whole sandwich-immunoassay was performed on one ICTS, greatly reducing analytical time. The ICTS sensor showed excellent linear responses for assaying total amount of BChE and active BChE ranging from 0.22 to 3.58nM and 0.22-7.17nM, respectively. Both the signal detection limits are 0.10nM. We validated the practical application of the proposed method to measure 124 human plasma samples from orchard workers and cotton farmers with long-term exposure to organophosphorus pesticides (OPs). The results were in highly agreement with LC/MS/MS which verified our method is extremely accurate. Combining the portability and rapidity of test strip and the compatibility of BChE MAb as both capture antibody and detection antibody, the developed method provides a baseline-free, low-cost and rapid tool for in-field monitoring of OP exposures.
一种基于夹心免疫测定法的免疫层析测试条(ICTS)已被开发出来,用于同时测量 70μL 暴露后人体血浆样品中的丁酰胆碱酯酶(BChE)活性和 BChE 的总量(包括抑制和活性酶)。该方法的原理基于能够作为捕获抗体和检测抗体的 BChE 单克隆抗体(MAb)。固定在测试线上的 BChE MAb 能够识别有机磷 BChE 加合物(OP-BChE)和 BChE,并提供相等的结合亲和力,从而能够检测暴露后人体血浆样品中的总酶量。测试线上形成的免疫复合物可以进一步从测试条上切下,随后使用 Ellman 测定法进行 BChE 活性的离线测量。因此,将同时获得 BChE 活性和磷酸化(OP-BChE)的双重生物标志物。整个夹心免疫测定在一个 ICTS 上进行,大大缩短了分析时间。ICTS 传感器在测定 BChE 总量和活性 BChE 的范围分别为 0.22-3.58nM 和 0.22-7.17nM 时表现出优异的线性响应。两种信号检测限均为 0.10nM。我们验证了该方法在测量长期接触有机磷农药(OPs)的果园工人和棉农的 124 个人体血浆样本中的实际应用。结果与 LC/MS/MS 高度一致,验证了我们的方法非常准确。结合测试条的便携性和快速性以及 BChE MAb 作为捕获抗体和检测抗体的兼容性,所开发的方法为现场监测 OP 暴露提供了一种无基线、低成本和快速的工具。