PURPOSE

To investigate the clinical survival and success rates of conventionally luted three- and four-unit fixed dental prostheses (FDPs) with zirconia frameworks (Cercon Smart Ceramics, DeguDent) after a mean observation period of 119 ± 36 months.

MATERIALS AND METHODS

A total of 75 patients were treated in the Department of Prosthodontics at the University of Goettingen, Germany, and a total of 99 posterior FDPs were inserted and luted with zinc phosphate cement. Time-dependent survival and success rates were calculated using Kaplan-Meier curves, and their relationships with the type of veneer (ceramic), location (maxilla vs mandible), and span length (three-unit vs four-unit) were analyzed with a Cox regression model (P < .05).

RESULTS

Of the 99 inserted FDPs, 24 were lost to follow-up, 51 remained functional and passed the 10-year examination (overall survival rate: 75.0%; 95% confidence interval [CI]: 0.64, 0.85), and 13 were absolute failures caused by technical events (technical survival rate: 84%; 95% CI: 0.64, 0.85). In 50 FDPs, relative failure required a clinical intervention to maintain function (overall success rate: 40%; 95% CI: 0.29, 0.52). For 35 of these FDPs, the relative failure was caused by technical events (technical success rate: 61%; 95% CI: 0.49, 0.73). None of the evaluated factors showed an association with overall or technical survival or success.

CONCLUSION

Zirconia-based posterior FDPs produced with a first-generation computer-assisted manufacturing (CAM) system revealed high rates of absolute and relative failure, mainly due to technical events, after a mean observational period of 10 years. Further clinical studies with updated computer-assisted design (CAD)/CAM systems are needed to determine the long-term performance of zirconia-based FDPs.

摘要

目的

研究采用氧化锆基架(Cercon Smart Ceramics,DeguDent)的传统粘结三单位和四单位固定义齿(FDP)在平均观察期119±36个月后的临床生存率和成功率。

材料与方法

德国哥廷根大学口腔修复科共治疗了75例患者,共植入99颗后牙FDP并用磷酸锌水门汀粘结。使用Kaplan-Meier曲线计算时间依赖性生存率和成功率,并通过Cox回归模型分析它们与饰面类型(陶瓷)、位置(上颌与下颌)和跨度长度(三单位与四单位)的关系(P <.05)。

结果

在植入的99颗FDP中,24颗失访,51颗仍能正常使用并通过了10年检查(总生存率:75.0%;95%置信区间[CI]:0.64,0.85),13颗因技术问题导致绝对失败(技术生存率:84%;95% CI:0.64,0.85)。在50颗FDP中,相对失败需要临床干预以维持功能(总成功率:40%;9