Suppr超能文献

带和不带激光微纹理颈圈的植入物:一项长达 10 年的临床和放射学比较评估。

Implants With and Without Laser-Microtextured Collar: A 10-Year Clinical and Radiographic Comparative Evaluation.

机构信息

Private Implant Practice, Lucca, Italy.

Associate Professor Program Director, Master's Program in Biomaterials Science, New York University College of Dentistry Biomaterials, New York, NY.

出版信息

Implant Dent. 2018 Feb;27(1):81-88. doi: 10.1097/ID.0000000000000718.

Abstract

INTRODUCTION

This article reports, after at least 10 years of follow-up, the comparative data of marginal bone loss (MBL) and periimplant soft tissue parameters, around implant with and without laser-microtextured (L) collar surface, previously reported at 3 years of follow-up.

MATERIALS AND METHODS

Twenty implants with L collar surface (test) were placed adjacent to 20 control implants with machined (M) collar surface in 15 partially edentulous patients, who were followed up for at least 10 years as part of a prospective longitudinal study. The plaque score, bleeding on probing (BoP) score, and probing depth (PD) were recorded at baseline and at each year follow-up examination. Mucosal recession (MR), and radiographic MBL were assessed at baseline and after at least 10 years.

RESULTS

Four patients were lost during follow-up, so the number of implants that have been followed for at least 10 years was 32 (16 tests and 16 controls). At the end of the follow-up period, no significant differences were found between the study groups regarding the presence of plaque and BoP (P > 0.05). A statistically significant difference between test and control implant was found for mean PD (2.3 ± 0.7 mm vs 3.8 ± 0.8), MBL (1.23 ± 0.21 mm vs 2.8 ± 0.9 mm), and mean MR (1.08 ± 0.4 mm vs 2.46 ± 0.3 mm).

CONCLUSION

Results suggest that after at least 10 years of function, implants with laser-microtexturing (L) collar surface, compared with implants with machined surface, lead to lower MBL and PD.

摘要

简介

本文报道了至少 10 年随访后,具有激光微纹理(L)颈圈表面的种植体和具有机械加工(M)颈圈表面的种植体的边缘骨丧失(MBL)和种植体周围软组织参数的对比数据,这些数据先前在 3 年随访时已经报道过。

材料和方法

在 15 名部分缺牙患者中,共放置了 20 个具有 L 颈圈表面的种植体(试验组)和 20 个具有机械加工颈圈表面的对照种植体(对照组)。作为前瞻性纵向研究的一部分,这些患者至少随访了 10 年。在基线和每年的随访检查中,记录菌斑指数、探诊出血(BoP)评分和探诊深度(PD)。在基线和至少 10 年后,评估了黏膜退缩(MR)和放射学 MBL。

结果

在随访过程中,有 4 名患者失访,因此至少随访了 10 年的种植体数量为 32 个(试验组 16 个,对照组 16 个)。在随访结束时,研究组之间在菌斑和 BoP 的存在方面没有发现显著差异(P > 0.05)。在平均 PD(2.3 ± 0.7 mm 比 3.8 ± 0.8)、MBL(1.23 ± 0.21 mm 比 2.8 ± 0.9 mm)和平均 MR(1.08 ± 0.4 mm 比 2.46 ± 0.3 mm)方面,试验组和对照组种植体之间存在统计学差异。

结论

结果表明,在功能至少 10 年后,与机械加工表面的种植体相比,具有激光微纹理(L)颈圈表面的种植体导致较低的 MBL 和 PD。