Suppr超能文献

一种通过改进简单无创I-123-IMP微球法开发的简单无创I-123-IMP放射自显影方法。

A Simple Non-invasive I-123-IMP Autoradiography Method Developed by Modifying the Simple Non-invasive I-123-IMP Microsphere Method.

作者信息

Ofuji Asato, Nagaoka Rieko, Yamashita Kosuke, Takaki Akihiro, Ito Shigeki

机构信息

Graduate School of Health Sciences, Kumamoto University, Kumamoto, Japan.

National Hospital Organization Kyushu Medical Center, Fukoka, Japan.

出版信息

Asia Ocean J Nucl Med Biol. 2018 Winter;6(1):50-56. doi: 10.22038/aojnmb.2017.9555.

Abstract

OBJECTIVES

We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR) to one-point WR. If the regional cerebral blood flow (rCBF) values derived from the SIARG and ARG methods correlate well, the facilities employing the ARG method can easily switch to the SIARG method. The purpose of this study was to develop the SIARG method by modifying the SIMS method, and to confirm the feasibility of this method.

METHODS

The correlation between the input counts of the SIARG method and the blood counts was determined by linear regression analysis. The rCBF values determined by the SIARG method were compared with the values obtained with the ARG and SIMS methods.

RESULTS

There was a good linear correlation between the SIARG counts and the arterial blood counts obtained by the ARG method (r=0.85, P<0.001, n=29). The rCBF values obtained by the ARG and SIARG methods (n=29, 696 ROIs) correlated well (y=1.01x - 3.6, r=0.85, P<0.001). Similarly, the rCBF values obtained by the SIARG and SIMS methods (n=29, 696 ROIs) correlated well (y=0.98x - 15.2, r=0.90, P<0.001). rCBF values obtained by the SIARG method were almost the same as the values obtained by the ARG method, and values of the SIMS method were 15 ml/100g/min higher that of those obtained by the SIARG method.

CONCLUSION

The rCBF values obtained by the ARG, SIARG, and SIMS methods correlated very well. Therefore, the SIARG method is potentially useful for examinations in routine clinical practice.

摘要

目的

我们通过基于微球模型分析胸部放射性核素血管造影和单光子发射计算机断层扫描(SPECT)图像,开发了一种简单的非侵入性I-123-N-异丙基-p-碘安非他明(I-IMP)定量方法(SIMS法)。理论上,通过将积分洗脱率(WR)修改为单点WR,SIMS法可转变为简单的非侵入性ARG(SIARG)法。如果SIARG法和ARG法得出的局部脑血流量(rCBF)值相关性良好,采用ARG法的机构可轻松转换为SIARG法。本研究的目的是通过修改SIMS法来开发SIARG法,并确认该方法的可行性。

方法

通过线性回归分析确定SIARG法的输入计数与血计数之间的相关性。将SIARG法确定的rCBF值与ARG法和SIMS法获得的值进行比较。

结果

SIARG计数与ARG法获得的动脉血计数之间存在良好的线性相关性(r=0.85,P<0.001,n=29)。ARG法和SIARG法获得的rCBF值(n=29,696个感兴趣区)相关性良好(y=1.01x - 3.6,r=0.85,P<0.001)。同样,SIARG法和SIMS法获得的rCBF值(n=29,696个感兴趣区)相关性良好(y=0.98x - 15.2,r=0.90,P<0.001)。SIARG法获得的rCBF值与ARG法获得的值几乎相同,SIMS法的值比SIARG法获得的值高15 ml/100g/min。

结论

ARG法、SIARG法和SIMS法获得的rCBF值相关性非常好。因此,SIARG法在常规临床实践检查中可能有用。