Harvey Hugh, Morgan Veronica, Fromageau Jeremie, O'Shea Tuathan, Bamber Jeffrey, deSouza Nandita M
1 Cancer Research UK Centre, The Institute of Cancer Research, Royal Marsden Hospital, Sutton, UK.
2 Joint Department of Physics, The Institute of Cancer Research, Royal Marsden Hospital, Sutton, UK.
Ultrason Imaging. 2018 May;40(3):158-170. doi: 10.1177/0161734618754487. Epub 2018 Jan 20.
The purpose of this study was to establish interobserver reproducibility of Young's modulus (YM) derived from ultrasound shear wave elastography (US-SWE) in the normal prostate and correlate it with multiparametric magnetic resonance imaging (mpMRI) tissue characteristics. Twenty men being screened for prostate cancer underwent same-day US-SWE (10 done by two blinded, newly-trained observers) and mpMRI followed by 12-core biopsy. Bland-Altman plots established limits of agreement for YM. Quantitative data from the peripheral zone (PZ) and the transitional zone (TZ) for YM, apparent diffusion coefficient (ADC, mm/s from diffusion-weighted MRI), and K (volume transfer coefficient, min), V (extravascular-extracellular space, %), K (rate constant, /min), and initial area under the gadolinium concentration curve (IAUGC60, mmol/L/s) from dynamic contrast-enhanced MRI were obtained for slice-matched prostate sextants. Interobserver intraclass correlation coefficients were fair to good for individual regions (PZ = 0.57, TZ = 0.65) and for whole gland 0.67, (increasing to 0.81 when corrected for systematic observer bias). In the PZ, there were weak negative correlations between YM and ADC ( p = 0.008), and Ve ( p = 0.01) and a weak positive correlation with K ( p = 0.003). No significant intermodality correlations were seen in the TZ. Transrectal prostate US-SWE done without controlling manually applied probe pressure has fair/good interobserver reproducibility in inexperienced observers with potential to improve this to excellent by standardization of probe contact pressure. Within the PZ, increase in tissue stiffness is associated with reduced extracellular water (decreased ADC) and space (reduced V).
本研究的目的是建立超声剪切波弹性成像(US-SWE)得出的正常前列腺组织杨氏模量(YM)的观察者间可重复性,并将其与多参数磁共振成像(mpMRI)组织特征相关联。20名接受前列腺癌筛查的男性在同一天接受了US-SWE检查(其中10例由两名不知情的新培训观察者进行)和mpMRI检查,随后进行了12针活检。Bland-Altman图确定了YM的一致性界限。从动态对比增强MRI获得了切片匹配的前列腺分区中外周带(PZ)和移行带(TZ)的YM、表观扩散系数(ADC,来自扩散加权MRI的mm/s)、K(容积转运系数,min)、V(血管外-细胞外间隙,%)、K(速率常数,/min)以及钆浓度曲线下的初始面积(IAUGC60,mmol/L/s)的定量数据。观察者间组内相关系数在各个区域(PZ = 0.57,TZ = 0.65)和整个腺体(0.67,校正系统观察者偏差后增至0.81)为中等至良好。在PZ中,YM与ADC(p = 0.008)和Ve(p = 0.01)之间存在弱负相关,与K存在弱正相关(p = 0.0 .003)。在TZ中未观察到显著的模态间相关性。在未手动控制探头压力的情况下进行经直肠前列腺US-SWE检查,在经验不足的观察者中具有中等/良好的观察者间可重复性,通过标准化探头接触压力有可能将其提高到优秀水平。在PZ内,组织硬度增加与细胞外水减少(ADC降低)和间隙减小(V降低)相关。