Nehmeh Sadek A, Schwartz Jazmin, Grkovski Milan, Yeung Ivan, Laymon Charles M, Muzi Mark, Humm John L
Weill Cornell Medical College, New York, NY, United States.
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
Clin Imaging. 2018 May-Jun;49:121-127. doi: 10.1016/j.clinimag.2017.12.015. Epub 2018 Jan 12.
To assess the inter-operator variability in compartment analysis (CA) of dynamic-FMISO (dyn-FMISO) PET.
Study-I: Five investigators conducted CA for 23 NSCLC dyn-FMISO tumor time-activity-curves. Study-II: Four operators performed CA for four NSCLC dyn-FMISO datasets. Repeatability of Kinetic-Rate-Constants (KRCs) was assessed.
Study-I: Strong correlation (ICC > 0.9) and interchangeable results among operators existed for all KRCs. Study-II: Up to 103% variability in tumor segmentation, and weaker ICC in KRCs (ICC-V = 0.53; ICC-K = 0.91; ICC-K/k = 0.25; ICC-k3 = 0.32; ICC-K = 0.54) existed. All KRCs were repeatable among the different operators.
Inter-operator variability in CA of dyn-FMISO was shown to be within statistical errors.