Abstract

PURPOSE

To evaluate the variability induced by the imager in discriminating high-grade (Gleason≥7) prostate cancers (HGC) using dynamic contrast-enhanced MRI.

MATERIAL AND METHODS

We retrospectively selected 3T MRIs with temporal resolution<10 seconds and comprising T1 mapping from a prospective radiologic-pathologic database of patients treated by prostatectomy. Ktrans, Kep, Ve and Vp were calculated for each lesion seen on MRI using the Weinmann arterial input function (AIF) and three patient-specific AIFs measured in the right and left iliac arteries in pixels in the center of the lumen (psAIF-ST) or manually selected by two independent readers (psAIF-R1 and psAIF-R2).

RESULTS

A total of 43 patients (mean age, 63.6±4.9 [SD]; range: 48-72 years) with 100 lesions on MRI (55 HGC) were selected. MRIs were performed on imager A (22 patients, 49 lesions) or B (21 patients, 51 lesions) from two different manufacturers. Using the Weinmann AIF, Kep (P=0.005), Ve (P=0.04) and Vp (P=0.01) significantly discriminated HCG. After adjusting on tissue classes, the imager significantly influenced the values of Kep (P=0.049) and Ve (P=0.007). Using patient-specific AIFs, Vp with psAIF-ST (P=0.008) and psAIF-R2 (P=0.04), and Kep with psAIF-R1 (P=0.03) significantly discriminated HGC. After adjusting on tissue classes, types of patient-specific AIF and side of measurement, the imager significantly influenced the values of Ktrans (P=0.0002), Ve (P=0.0072) and Vp (P=0.0003). For all AIFs, the diagnostic value of pharmacokinetic parameters remained unchanged after adjustment on the imager, with stable odds ratios.

CONCLUSION

The imager induced variability in the absolute values of pharmacokinetic parameters but did not change their diagnostic performance.

摘要

目的

评估利用动态对比增强 MRI 成像仪区分高级别(Gleason≥7)前列腺癌(HGC)的变异性。

材料与方法

我们从接受前列腺切除术治疗的患者前瞻性放射病理学数据库中回顾性选择了时间分辨率<10 秒的 3T MRI 及 T1 映射。使用 Weinmann 动脉输入函数(AIF)和在右侧和左侧髂动脉中心管腔的像素(psAIF-ST)或由两名独立读者手动选择(psAIF-R1 和 psAIF-R2)的三个患者特定的 AIF 计算在 MRI 上看到的每个病变的 Ktrans、Kep、Ve 和 Vp。

结果

共选择了 43 名患者(平均年龄,63.6±4.9[SD];范围:48-72 岁),MRI 上有 100 个病变(55 个 HGC)。MRI 由来自两个不同制造商的成像仪 A(22 名患者,49 个病变)或 B(21 名患者,51 个病变)进行。使用 Weinmann AIF,Kep(P=0.005)、Ve(P=0.04)和 Vp(P=0.01)显著区分了 HGC。调整组织类别后,成像仪显著影响 Kep(P=0.049)和 Ve(P=0.007)的值。使用患者特定的 AIF,psAIF-ST(P=0.008)和 psAIF-R2(P=0.04)的 Vp 和 psAIF-R1(P=0.03)的 Kep 显著区分了 HGC。调整组织类别、患者特定 AIF 类型和测量侧后,成像仪显著影响 Ktrans(P=0.0002)、Ve(P=0.0072)和 Vp(P=0.0003)的值。对于所有 AIF,在调整成像仪后,药代动力学参数的诊断价值保持不变,且比值比稳定。

结论

成像仪引起药代动力学参数绝对值的变异性,但不改变其诊断性能。