Suppr超能文献

磁共振弹性成像对小肾肿瘤的特征分析:一项可行性研究。

Characterization of Small Renal Tumors With Magnetic Resonance Elastography: A Feasibility Study.

出版信息

Invest Radiol. 2018 Jun;53(6):344-351. doi: 10.1097/RLI.0000000000000449.

Abstract

OBJECTIVES

The aim of this study was to explore the feasibility of magnetic resonance elastography (MRE) for characterizing indeterminate small renal tumors (SRTs) as part of a multiparametric magnetic resonance (MR) imaging protocol.

MATERIALS AND METHODS

After institutional review board approval and informed consent were obtained, 21 prospective adults (15 men; median age, 55 years; age range, 25-72 years) with SRT were enrolled. Tumors (2-5 cm Ø) were imaged using 3-directional, gradient echo MRE. Viscoelastic parametric maps (shear wave velocity [c] and attenuation [α]) were analyzed by 2 independent radiologists. Interobserver agreement (Bland-Altman statistics and intraclass correlation coefficients) was assessed. Anatomical T2-weighted, dynamic contrast-enhanced (DCE) and diffusion sequences completed the acquisition protocol. Imaging parameters were compared between groups (Mann-Whitney U test).

RESULTS

Quality of MRE was good in 18 cases (mean nonlinearity <50%), including 1 papillary renal cell carcinoma and 1 metanephric adenoma. A cohort of 5 oncocytomas and 11 clear-cell renal cell carcinomas (ccRCCs) was analyzed for statistical differences. The MRE viscoelastic parameters were the strongest imaging discriminators: oncocytomas displayed significantly lower shear velocity c (median, 0.77 m/s; interquartile range [IQR], 0.76-0.79) (P = 0.007) and higher shear attenuation α (median, 0.087 mm; IQR, 0.082-0.087) (P = 0.008) than ccRCC (medians, 0.92 m/s and 0.066 mm; IQR, 0.84-0.97 and 0.054-0.074, respectively). T2 signal intensity ratio (tumor/renal cortex) was lower in oncocytomas (P = 0.02). The DCE and diffusion MR parameters overlapped substantially (P ≥ 0.1). Oncocytomas displayed a consistent MRE viscoelastic profile, corresponding to data point clustering in a bidimensional scatter plot. Values for MRE intraclass correlation coefficient were 0.982 for c and 0.984 for α, indicating excellent interobserver agreement.

CONCLUSIONS

Magnetic resonance elastography is feasible for SRT characterization; MRE viscoelastic parameters were stronger discriminators between oncocytoma and ccRCC than anatomical, DCE and diffusion MR imaging parameters.

摘要

目的

本研究旨在探讨磁共振弹性成像(MRE)在多参数磁共振成像(MR)方案中对不确定小肾肿瘤(SRT)进行特征描述的可行性。

材料与方法

本研究经机构审查委员会批准并获得患者知情同意后,共纳入 21 例 SRT 前瞻性成年患者(15 名男性;中位年龄 55 岁;年龄范围 25-72 岁)。采用 3 个方向的梯度回波 MRE 对肿瘤(2-5cmØ)进行成像。由 2 名独立的放射科医生分析黏弹性参数图(剪切波速度[c]和衰减[α])。评估了观察者间的一致性(Bland-Altman 统计和组内相关系数)。完成采集方案后,还进行了解剖 T2 加权、动态对比增强(DCE)和弥散序列。使用 Mann-Whitney U 检验对组间的成像参数进行比较。

结果

18 例(平均非线性度<50%)的 MRE 质量良好,包括 1 例肾细胞乳头状癌和 1 例后肾腺瘤。对 5 例嗜酸细胞瘤和 11 例透明细胞肾细胞癌(ccRCC)进行了统计学差异分析。MRE 黏弹性参数是最强的影像学鉴别指标:嗜酸细胞瘤的剪切波速度 c 明显较低(中位数 0.77m/s;四分位距 [IQR] 0.76-0.79)(P=0.007),剪切衰减α较高(中位数 0.087mm;IQR 0.082-0.087)(P=0.008),而 ccRCC 的剪切波速度 c 和剪切衰减α分别为(中位数 0.92m/s 和 0.066mm;IQR 0.84-0.97 和 0.054-0.074)(P<0.05)。嗜酸细胞瘤的 T2 信号强度比(肿瘤/肾皮质)较低(P=0.02)。DCE 和弥散 MR 参数之间有很大的重叠(P≥0.1)。嗜酸细胞瘤显示出一致的 MRE 黏弹性特征,这与二维散点图中的数据点聚类相对应。MRE 组内相关系数的数值为 c 为 0.982,α为 0.984,表明观察者间的一致性很好。

结论

磁共振弹性成像可用于 SRT 特征描述;与解剖学、DCE 和弥散 MR 成像参数相比,MRE 黏弹性参数是嗜酸细胞瘤与 ccRCC 之间更强的鉴别指标。