Ganser Philipp, Baum Christoph, Chargin David, Sauer-Budge Alexis F, Sharon Andre
Fraunhofer Institute for Production Technology IPT, Aachen, Germany.
Center for Manufacturing Innovation, Fraunhofer USA, Brookline, MA, 02446, USA.
Biomed Microdevices. 2018 Feb 24;20(2):24. doi: 10.1007/s10544-018-0265-9.
A reduced channel height in microfluidic Lab-on-a-Chip (LOC) devices enables a reduction in the required volume of sample and reagents. LOC devices are most often manufactured by microstructuring a planar substrate and subsequently sealing it with a cover film. However, shallow chip designs, made from polymers, are sensitive to channel deformation during the sealing of the microfluidic device. Inappropriate bonding conditions often result in the loss of the microfluidic functionality. A systematic and practical approach for the identification of suitable bonding process parameters is missing. In this article, a straightforward approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from Cyclic Olefin Polymer (COP) is presented. Two COP materials were tested: COP Zeonex 690R (Glass transition temperature T = 135 °C) both as a cover film and substrate material, and COP ZF14 (T = 135 °C) as a film material. A mechanical analysis using microstructured Zeonex 690R substrates was performed to generate a matrix of low-distortion bonding parameters, including temperature, pressure and time. The well-established method of solvent-assisted bonding was used to enhance the characteristically low bond strengths of the native COP material. In addition, plasma-assisted bonding was tested and compared. The optimization approach was validated by the manufacture of a microfluidic test device, the demonstration of its microfluidic functionality, and the quantitative evaluation of the achieved channel integrity.
微流控芯片实验室(LOC)设备中通道高度的降低能够减少所需的样品和试剂体积。LOC设备通常是通过对平面基板进行微结构化处理,然后用覆盖膜密封来制造的。然而,由聚合物制成的浅芯片设计在微流控设备密封过程中对通道变形很敏感。不合适 的键合条件常常会导致微流控功能丧失。目前缺少一种用于确定合适键合工艺参数的系统且实用的方法。在本文中,提出了一种直接的方法,用于优化由环烯烃聚合物(COP)制成的浅微流控设备密封过程中的通道完整性。测试了两种COP材料:COP Zeonex 690R(玻璃化转变温度T = 135°C)既作为覆盖膜又作为基板材料,以及COP ZF14(T = 135°C)作为薄膜材料。使用微结构化的Zeonex 690R基板进行了力学分析,以生成包括温度、压力和时间在内的低变形键合参数矩阵。采用成熟的溶剂辅助键合方法来提高天然COP材料通常较低的键合强度。此外,还对等离子体辅助键合进行了测试和比较。通过制造微流控测试设备、展示其微流控功能以及对所实现的通道完整性进行定量评估,验证了该优化方法。