Suppr超能文献

有和无囊袋张力环的散光型人工晶状体的旋转稳定性和视觉效果的对比评估。

Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.

机构信息

Department of Ophthalmology, Guru Nanak Eye Centre and Maulana Azad Medical College, New Delhi, India.

出版信息

Indian J Ophthalmol. 2018 Mar;66(3):411-415. doi: 10.4103/ijo.IJO_875_17.

Abstract

PURPOSE

To evaluate the rotational stability of toric intraocular lens (IOL) when co-implanted with a capsular tension ring (CTR) as compared to that of a toric IOL without a CTR.

METHODS

This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism ≥1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count <2000/mm were excluded from the study. The eyes in both the groups underwent standard phacoemulsification and were implanted with a toric IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally.

RESULTS

Mean rotation of toric IOL at 3 months postoperatively was 1.85 ± 1.72° in Group A and 4.02 ± 2.04° in Group B. The difference was statistically significant (P = 0.003).

CONCLUSION

Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.

摘要

目的

评估与未使用囊袋张力环(CTR)的散光型人工晶状体(IOL)相比,联合使用 CTR 时散光型 IOL 的旋转稳定性。

方法

这是在印度一家三级护理中心进行的前瞻性随机临床试验。50 只成人眼患有明显的白内障和≥1.5D 的规则性角膜散光,通过简单随机化将其分为两组,每组 25 只眼,分别为 A 组和 B 组。排除有角膜病变、晶状体半脱位和镜面内皮细胞计数<2000/mm 的眼。两组眼均行标准超声乳化白内障吸除术,并植入散光型 IOL。在 A 组,在 IOL 植入前将 CTR 置于囊袋内。术后第 1、1 周、1 个月和 3 个月对两组患者进行随访。每次随访时,通过反射照明下的裂隙灯成像测量散光型 IOL 的轴位,并进行数字分析。

结果

术后 3 个月,A 组散光型 IOL 的平均旋转角度为 1.85±1.72°,B 组为 4.02±2.04°。差异具有统计学意义(P=0.003)。

结论

联合使用 CTR 是一种安全有效的技术,可确保散光型 IOL 更好的旋转稳定性。