Suppr超能文献

对私人诊所中植入的1087颗阳极氧化种植体的回顾性研究:与种植体失败相关的风险指标以及骨水平与软组织健康之间的关系。

Retrospective Study of 1087 Anodized Implants Placed in Private Practice: Risk Indicators Associated With Implant Failure and Relationship Between Bone Levels and Soft Tissue Health.

作者信息

French David, Larjava Hannu, Tallarico Marco

机构信息

Private Practice Calgary, AB, Canada.

Faculty, Division of Periodontics, Department of Oral Biological & Medical Science, Faculty of Dentistry, The University of British Columbia, Vancouver, BC, Canada.

出版信息

Implant Dent. 2018 Apr;27(2):177-187. doi: 10.1097/ID.0000000000000743.

Abstract

INTRODUCTION

To evaluate risk indicators associated with implant failure and relationship between bone levels and soft-tissue health of anodized implants placed in private practice.

MATERIAL AND METHODS

Partially or completely edentulous patients who received an anodized implant between 2003 and 2013 were included. Univariate and multivariate analysis was used to identify the relationship between study variables and implant failure. Mean marginal bone level changes (MBLΔ) were assessed using periapical radiographs. Periimplant soft tissue was evaluated using a modified bleeding index (implant mucosal index, IMI).

RESULTS

A total of 1087 implants placed in 414 patients were followed for 3.9 ± 2.7 years. The cumulative implant survival rate after 10 years of function was 97.0%. Shorter (P = 0.0068) and maxillary implants (P = 0.0314) were associated with lower implant survival rate. Mean MBL decreased from -0.16 ± 0.43 mm at baseline to -0.53 ± 0.53 mm 8 to 10 years later. Implants with healthier mucosa were associated with less bone loss.

CONCLUSIONS

Implants with an anodized surface showed a high long-term survival rate in a daily practice. Longer implants and implants placed in the mandible were associated with greater survival. Immediate loading and tapered design did not affect implant survival. Profuse multipoint bleeding and suppuration on recall were associated with greater bone loss.

摘要

引言

评估在私人诊所植入的阳极氧化种植体的植入失败相关风险指标以及骨水平与软组织健康之间的关系。

材料与方法

纳入2003年至2013年间接受阳极氧化种植体的部分或完全无牙患者。采用单因素和多因素分析来确定研究变量与种植体失败之间的关系。使用根尖片评估平均边缘骨水平变化(MBLΔ)。使用改良出血指数(种植体黏膜指数,IMI)评估种植体周围软组织。

结果

对414例患者植入的1087枚种植体进行了3.9±2.7年的随访。功能10年后的种植体累积生存率为97.0%。较短的种植体(P = 0.0068)和上颌种植体(P = 0.0314)与较低的种植体生存率相关。平均MBL从基线时的-0.16±0.43mm降至8至10年后的-0.53±0.53mm。黏膜更健康的种植体骨丢失较少。

结论

在日常临床中,具有阳极氧化表面的种植体显示出较高的长期生存率。较长的种植体和下颌种植体的生存率更高。即刻加载和锥形设计不影响种植体生存率。复诊时大量多点出血和化脓与更多的骨丢失相关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验