Suppr超能文献

不同 MOD 洞型尺寸黏结修复后磨牙的体外抗折性能。

In Vitro Fracture Resistance of Adhesively Restored Molar Teeth with Different MOD Cavity Dimensions.

机构信息

Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, Szeged, Hungary.

Department of Oral Surgery, Faculty of Dentistry University of Szeged, Szeged, Hungary.

出版信息

J Prosthodont. 2019 Jan;28(1):e325-e331. doi: 10.1111/jopr.12777. Epub 2018 Mar 5.

Abstract

PURPOSE

Molar MOD (mesial-occlusal-distal) cavity preparation weakens relative cuspal stiffness by up to 63%, often resulting in cuspal fracture. This investigation inspects fracture resistance of MOD cavities restored using direct composite restoration.

MATERIALS AND METHODS

120 extracted, intact mandibular molars were selected. MOD cavities with different depth/wall thickness were prepared in 9 groups (n = 12): A: 3 mm/3.5 mm, B: 3 mm/2.5 mm, C: 3 mm/1.5 mm, D: 5 mm/3.5 mm, E: 5 mm/2.5 mm, F: 5 mm/1.5 mm, G: 7 mm/3.5 mm, H: 7 mm/2.5 mm, I: 7 mm/1.5 mm. Specimens with 7 mm deep cavities received root canal treatment. The teeth were restored with dental composite. Maximal fracture strength test was conducted. Intact natural teeth were used as control. For statistical analysis Kruskal-Wallis ANOVA with post-hoc pairwise comparisons was used (α = 0.05).

RESULTS

Significant difference was indicated between the control and groups D, E, F, G, H, and I. No significant differences were found between the A, B, C groups and the control. Comparing the 5 and 7 mm cavity depth groups, there was no statistical difference between any of them.

CONCLUSIONS

Within the limitations of this investigation, the following conclusions can be drawn regarding molar teeth with a MOD cavity: 3 mm or shallower cavities can be restored to the physiological fracture strength with direct composite restorations; 5 mm or deeper cavities cannot be restored to the physiological fracture strength with direct composite restorations. Cusp thickness does not significantly influence fracture strength in molar MOD cavities with a direct composite restoration.

摘要

目的

磨牙近中-牙合-远中(MOD)窝洞预备会使相对牙尖强度降低高达 63%,常导致牙尖折裂。本研究旨在检查使用直接复合树脂修复体修复 MOD 窝洞后的抗折裂能力。

材料和方法

选择 120 颗完整的下颌磨牙。在 9 组(每组 12 个)中制备不同深度/壁厚度的 MOD 窝洞:A:3mm/3.5mm,B:3mm/2.5mm,C:3mm/1.5mm,D:5mm/3.5mm,E:5mm/2.5mm,F:5mm/1.5mm,G:7mm/3.5mm,H:7mm/2.5mm,I:7mm/1.5mm。深度为 7mm 的窝洞进行根管治疗。用牙科复合树脂修复牙齿。进行最大断裂强度测试。将完整的天然牙齿用作对照。采用 Kruskal-Wallis ANOVA 进行统计分析,并进行事后两两比较(α=0.05)。

结果

与对照组相比,D、E、F、G、H 和 I 组之间存在显著差异。A、B、C 组与对照组之间无显著差异。比较 5mm 和 7mm 窝洞深度组,它们之间没有统计学差异。

结论

在本研究的限制范围内,可以得出以下结论:对于具有 MOD 窝洞的磨牙,3mm 或更浅的窝洞可以用直接复合树脂修复体恢复到生理断裂强度;5mm 或更深的窝洞不能用直接复合树脂修复体恢复到生理断裂强度。在使用直接复合树脂修复磨牙 MOD 窝洞时,牙尖厚度对牙尖抗折裂强度没有显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验