Suppr超能文献

健康角膜中角膜向后光散射的评估及影响角膜透明度的因素。

Assessment of corneal backward light scattering in the healthy cornea and factors affecting corneal transparency.

作者信息

Cankaya Ali Bulent, Tekin Kemal, Kiziltoprak Hasan, Karahan Sevilay, Yilmazbas Pelin

机构信息

Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Sıhhiye, 06100, Ankara, Turkey.

Ophthalmology Department, Kars State Hospital, Kars, Turkey.

出版信息

Jpn J Ophthalmol. 2018 May;62(3):335-341. doi: 10.1007/s10384-018-0584-7. Epub 2018 Mar 16.

Abstract

PURPOSE

To quantify normative corneal optical density (COD) values of healthy individuals and to investigate alterations in the COD in relation to their ocular and demographic characteristics.

STUDY DESIGN

Prospective, cross-sectional, and observational.

METHODS

In total, 588 eyes from 588 healthy participants with clear corneas were consecutively enrolled. Corneal densitometry values expressed in standardized grayscale units (GSU) from different corneal layers and zones obtained using the rotating Pentacam Scheimpflug system were analyzed.

RESULTS

The mean (SD) COD over the 12-mm diameter area was 14.4 ± 2.74 GSU. A significant positive correlation was found between the participants' age and the total COD (r = 0.756, P < .001). No significant differences were found between males and females with respect to COD (P = .51). No significant correlation was found between the COD measurements and refractive error, pachymetry, and keratometry (P > .05 for all comparisons). On the other hand, COD was negatively correlated with white-to-white (WTW) corneal diameter (r = - 0.415, P < .001). Moreover, the WTW corneal diameter was correlated with the COD in any zone and layer of the cornea (P < .05 for all comparisons).

CONCLUSIONS

Wide variations in COD can be detected even in corneas deemed clinically clear. Age and corneal diameter that seem to influence corneal transparency should be taken into account when evaluating corneal backscatter.

摘要

目的

量化健康个体的规范性角膜光学密度(COD)值,并研究COD与眼部及人口统计学特征相关的变化情况。

研究设计

前瞻性、横断面观察性研究。

方法

连续纳入588名角膜透明的健康参与者的588只眼。分析使用旋转式Pentacam Scheimpflug系统获得的不同角膜层和区域以标准化灰度单位(GSU)表示的角膜密度测量值。

结果

12毫米直径区域的平均(标准差)COD为14.4±2.74 GSU。参与者年龄与总COD之间存在显著正相关(r = 0.756,P <.001)。男性和女性在COD方面无显著差异(P =.51)。COD测量值与屈光不正、角膜厚度测量和角膜曲率测量之间未发现显著相关性(所有比较的P >.05)。另一方面,COD与角膜白到白(WTW)直径呈负相关(r = -0.415,P <.001)。此外,WTW角膜直径与角膜任何区域和层的COD均相关(所有比较的P <.05)。

结论

即使在临床认为透明的角膜中也能检测到COD的广泛差异。在评估角膜后向散射时,应考虑似乎影响角膜透明度的年龄和角膜直径。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验