站立未镇静马匹右心房和心室单相动作电位及不应期测量的测量变异性

Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse.

作者信息

De Clercq Dominique, Broux Barbara, Vera Lisse, Decloedt Annelies, van Loon Gunther

机构信息

Department of Large Animal Internal Medicine, Ghent University, Salisburylaan 133, B-9820, Merelbeke, Belgium.

出版信息

BMC Vet Res. 2018 Mar 20;14(1):101. doi: 10.1186/s12917-018-1399-y.

Abstract

BACKGROUND

In human and veterinary medicine, monophasic action potential (MAP) analysis and determination of local refractory periods by contact electrode technique gives valuable information about local cardiac electrophysiological properties. It is used to investigate dysrhythmias and the impact of drugs on the myocardium. Precise measurement of total MAP duration is difficult, therefore the MAP duration is usually determined at a repolarization level of 90% (APD90). Until now, no studies are published about the feasibility of this technique in the standing non-sedated horse. In 6 healthy Warmblood horses, on two different days, an 8F quadripolar contact catheter was passed through a jugular introducer sheath and placed under ultrasound guidance at the level of the intervenous tubercle or right atrial free wall (RA), and in the right ventricular apex (RV) to record the MAP. The MAP amplitude and APD90 were measured at a resting sinus rhythm (heart rate of 30-42 bpm) and at pacing cycle lengths (PCL) of 1000 and 600 ms. The effective refractory period (ERP) was determined at PCL of 1000 and 600 ms.

RESULTS

The overall mean (±SD) APD90 (rest), APD90 (1000) and APD90 (600) were 263 ± 39 ms, 262 ± 41 ms, 236 ± 47 ms for the RA and 467 ± 23 ms, 412 ± 38 ms, 322 ± 29 ms for the RV. The mean ERP1000 and ERP600 were 273 ± 24 ms and 256 ± 22 ms for the RA and 386 ± 40 ms and 293 ± 30 ms for the RV. The measurement variability for the amplitude, APD90 and ERP measurements in the RA ranged between 36 and 44, 9-22 and 7-8%, respectively. The measurement variability for the amplitude, APD90 and ERP measurements in the RV ranged between 49 and 66, 6-7 and 10-12%, respectively.

CONCLUSIONS

RA and RV MAP duration and ERP can be obtained by a contact electrode in standing non-sedated horses. The measurement variability varies with catheter location.

摘要

背景

在人类和兽医学中,通过接触电极技术进行单相动作电位(MAP)分析和局部不应期测定,可提供有关局部心脏电生理特性的有价值信息。它用于研究心律失常以及药物对心肌的影响。精确测量总MAP持续时间很困难,因此通常在复极化水平为90%(APD90)时测定MAP持续时间。到目前为止,尚未有关于该技术在站立非镇静马匹中可行性的研究发表。在6匹健康温血马中,于两个不同日期,将一根8F四极接触导管经颈静脉导入鞘管,在超声引导下置于静脉结节或右心房游离壁(RA)水平以及右心室尖部(RV),以记录MAP。在静息窦性心律(心率30 - 42次/分钟)以及起搏周期长度(PCL)为1000和600毫秒时测量MAP幅度和APD90。在PCL为1000和600毫秒时测定有效不应期(ERP)。

结果

RA的总体平均(±标准差)APD90(静息)、APD90(1000)和APD90(600)分别为263±39毫秒、262±41毫秒、236±47毫秒,RV的分别为467±23毫秒、412±38毫秒、322±29毫秒。RA的平均ERP1000和ERP600分别为273±24毫秒和256±22毫秒,RV的分别为386±40毫秒和293±30毫秒。RA中幅度、APD90和ERP测量的测量变异性分别在36%至44%、9%至22%和7%至8%之间。RV中幅度、APD90和ERP测量的测量变异性分别在49%至66%、6%至7%和10%至12%之间。

结论

通过接触电极可在站立非镇静马匹中获得RA和RV的MAP持续时间及ERP。测量变异性随导管位置而异。