Suppr超能文献

载抗生素硫酸钙珠粒与脉冲冲洗在体外可根除金属植入材料上的生物膜。

Antibiotic loaded calcium sulfate bead and pulse lavage eradicates biofilms on metal implant materials in vitro.

作者信息

Knecht Cory S, Moley James P, McGrath Mary S, Granger Jeffrey F, Stoodley Paul, Dusane Devendra H

机构信息

Department of Orthopaedics, Cleveland Clinic, Akron General, Akron, Ohio.

Department of Microbial Infection and Immunity, The Ohio State University, 716 Biomedical Research Tower (BRT), 460 W 12th Ave, Columbus, Ohio 43210.

出版信息

J Orthop Res. 2018 Sep;36(9):2349-2354. doi: 10.1002/jor.23903. Epub 2018 Apr 24.

Abstract

Pulse lavage (PL) debridement and antibiotic loaded calcium sulfate beads (CS-B) are both used for the treatment of biofilm related periprosthetic joint infection (PJI). However, the efficacy of these alone and in combination for eradicating biofilm from orthopaedic metal implant surfaces is unclear. The purpose of the study was to understand the efficacy of PL and antibiotic loaded CS-B in eradicating bacterial biofilms on 316L stainless steel (SS) alone and in combination in vitro. Biofilms of bioluminescent strains of Pseudomonas aeruginosa Xen41 and a USA300 MRSA Staphylococcus aureus SAP231 were grown on SS coupons for 3 days. The coupons were either, (i) debrided for 3 s with PL, (ii) exposed to tobramycin (TOB) and vancomycin (VAN) loaded CS-B for 24 h, or (iii) exposed to both. An untreated biofilm served as a control. The amount of biofilm was measured by bioluminescence, viable plate count and confocal microscopy using live/dead staining. PL alone reduced the CFU count of both strains of biofilms by approximately 2 orders of magnitude, from an initial cell count on metal surface of approximately 10 CFU/cm . The antibiotic loaded CS-B caused an approximate six log reduction and the combination completely eradicated viable biofilm bacteria. Bioluminescence and confocal imaging corroborated the CFU data. While PL and antibiotic loaded CS-B both significantly reduced biofilm, the combination of two was more effective than alone in removing biofilms from SS implant surfaces. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2349-2354, 2018.

摘要

脉冲冲洗(PL)清创术和载抗生素硫酸钙珠(CS-B)均用于治疗与生物膜相关的人工关节周围感染(PJI)。然而,单独使用或联合使用这些方法从骨科金属植入物表面根除生物膜的疗效尚不清楚。本研究的目的是了解PL和载抗生素CS-B单独及联合使用在体外根除316L不锈钢(SS)表面细菌生物膜的疗效。铜绿假单胞菌Xen41和USA300耐甲氧西林金黄色葡萄球菌SAP231的生物发光菌株在SS试片上培养3天。将试片分别进行以下处理:(i)用PL清创3秒;(ii)暴露于载有妥布霉素(TOB)和万古霉素(VAN)的CS-B中24小时;或(iii)同时进行上述两种处理。未处理的生物膜作为对照。通过生物发光、活菌平板计数和使用活/死染色的共聚焦显微镜测量生物膜的量。单独使用PL可使两种生物膜菌株的CFU计数降低约2个数量级,从金属表面的初始细胞计数约10 CFU/cm²开始。载抗生素的CS-B可使CFU计数降低约6个对数,联合使用则可完全根除活的生物膜细菌。生物发光和共聚焦成像证实了CFU数据。虽然PL和载抗生素的CS-B均能显著减少生物膜,但两者联合使用在从SS植入物表面去除生物膜方面比单独使用更有效。© 2018骨科研究协会。由Wiley Periodicals, Inc.出版。《矫形外科学研究》36:2349 - 2354, 2018年。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验